Detection of 22 antiepileptic drugs by ultra‐performance liquid chromatography coupled with tandem mass spectrometry applicable to routine therapeutic drug monitoring
Reproducibility of Results
Sensitivity and Specificity
01 natural sciences
0104 chemical sciences
Drug Stability
Limit of Detection
Tandem Mass Spectrometry
Linear Models
Humans
Anticonvulsants
Drug Monitoring
Chromatography, High Pressure Liquid
DOI:
10.1002/bmc.2726
Publication Date:
2012-03-01T16:43:04Z
AUTHORS (6)
ABSTRACT
ABSTRACTThe purpose of this study was to develop an ultra‐performance liquid chromatography tandem mass spectrometry (UPLC‐MS/MS) method of 22 antiepileptics for routine therapeutic monitoring. The antiepileptics used in the analyses were carbamazepine, carbamazepine‐10,11‐epoxide, clobazam, N‐desmethylclobazam, clonazepam, diazepam, N‐desmethyldiazepam, ethosuximide, felbamate, gabapentin, lamotrigine, levetiracetam, N‐desmethylmesuximide, nitrazepam, phenobarbital, phenytoin, primidone, tiagabine, topiramate, valproic acid, vigabatrin and zonisamide. After protein precipitation of 50 μL plasma with methanol, the supernatant was diluted with water or was evaporated to dryness and reconstituted with mobile phase in the case of benzodiazepines. Separation was achieved on an Acquity UPLC BEH C18 column with a gradient mobile phase of 10 mm ammonium acetate containing 0.1% formic acid and methanol at a flow rate of 0.4 mL/min. An Acquity TQD instrument in multiple reaction monitoring mode with ion mode switching was used for detection. All antiepileptics were detected and quantified within 10 min, with no endogenous interference. All the calibration curves showed good linearity in the therapeutic range (r2 < 0.99). The precision and accuracy values for intra‐ and inter‐assays were within ±15% except for phenobarbital and tiagabine. A good correlation was observed between the concentration of clinical samples measured by the new method described here and the conventional methods. The values of carbamazepine and phenytoin by UPLC‐MS/MS were lower than those detected by the immunoassays, which might be caused by the cross‐reaction of antibodies with their metabolites. In conclusion, we developed a simple and selective UPLC‐MS/MS method suitable for routine therapeutic monitoring of antiepileptics. Copyright © 2012 John Wiley & Sons, Ltd.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (20)
CITATIONS (76)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....