Measurement of spleen fat on MRI-proton density fat fraction arises from reconstruction of noise
Artifactual
Adult
Male
Magnetic Resonance Spectroscopy
Adolescent
Signal-To-Noise Ratio
Imaging
Fat quantification
03 medical and health sciences
Computer-Assisted
Imaging, Three-Dimensional
0302 clinical medicine
Clinical Research
Image Interpretation, Computer-Assisted
Humans
Prospective Studies
Child
Image Interpretation
Spectroscopy
screening and diagnosis
Middle Aged
Magnetic Resonance Imaging
4.1 Discovery and preclinical testing of markers and technologies
3. Good health
Detection
Adipose Tissue
CSE-MRI
Three-Dimensional
Biomedical Imaging
Female
Algorithms
Spleen
DOI:
10.1007/s00261-019-02079-z
Publication Date:
2019-06-06T09:02:36Z
AUTHORS (11)
ABSTRACT
This study compares splenic proton density fat fraction (PDFF) measured using confounder-corrected chemical shift-encoded (CSE)-MRI to magnetic resonance spectroscopy (MRS) in human patients at 3T.This was a prospectively designed ancillary study to various previously described single-center studies performed in adults and children with known or suspected nonalcoholic fatty liver disease. Patients underwent magnitude-based MRI (MRI-M), complex-based MRI (MRI-C), high signal-to-noise variants (Hi-SNR MRI-M and Hi-SNR MRI-C), and MRS at 3T for spleen PDFF estimation. PDFF from CSE-MRI methods were compared to MRS-PDFF using Wilcoxon signed-rank tests. Demographics were summarized descriptively. Spearman's rank correlations were computed pairwise between CSE-MRI methods. Individual patient measurements were plotted for qualitative assessment. A significance level of 0.05 was used.Forty-seven patients (20 female, 27 male) including 12 adults (median 55 years old) and 35 children (median 12 years old). Median PDFF estimated by MRS, MRI-M, Hi-SNR MRI-M, MRI-C, and Hi-SNR MRI-C was 1.0, 2.3, 1.9, 2.2, and 2.0%. The four CSE-MRI methods estimated statistically significant higher spleen PDFF values compared to MRS (p < 0.0001 for all). Pairwise associations in spleen PDFF values measured by different CSE-MRI methods were weak, with the highest Spearman's rank correlations being 0.295 between MRI-M and Hi-SNR MRI-M; none were significant after correction for multiple comparisons. No qualitative relationship was observed between PDFF measurements among the various methods.Overestimation of PDFF by CSE-MRI compared to MRS and poor agreement between related CSE-MRI methods suggest that non-zero PDFF values in human spleen are artifactual.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (41)
CITATIONS (7)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....