Application of DynaCT angiographic reconstruction in balloon pulmonary angioplasty
Male
Computed Tomography Angiography
Contrast Media
Reproducibility of Results
Middle Aged
Pulmonary Artery
03 medical and health sciences
Imaging, Three-Dimensional
0302 clinical medicine
Image Processing, Computer-Assisted
Humans
Female
Pulmonary Embolism
Lung
Angioplasty, Balloon
Aged
Retrospective Studies
DOI:
10.1007/s00330-020-07028-9
Publication Date:
2020-07-03T10:02:37Z
AUTHORS (8)
ABSTRACT
To investigate the feasibility and accuracy of balloon pulmonary angioplasty (BPA) using DynaCT angiographic reconstruction guidance.Thirty-four BPAs (23 CTEPH patients) targeting 175 pulmonary arteries were included. Eleven BPAs (2D group) were guided by DSA two-dimensional angiography. Another twenty-three BPAs (3D group) were guided using DynaCT angiographic reconstruction. The volume rendering (VR) method was used to obtain a three-dimensional image of the blood vessels. This image was used as a reference to continue BPA treatment under the guidance of vascular three-dimensional reconstruction technology. Procedure durations and radiation exposure data were compared between the two groups using Mann-Whitney U test.Using the DynaCT angiographic reconstruction technique, more target vessels were treated in a single BPA procedure (5.83 ± 2.33 vs 3.73 ± 1.10 vessels per BPA, p = 0.008) in a shorter operation time (3.58 ± 0.61 vs 4.49 ± 0.91 h, p = 0.002). Overall, the dose area product (DAP) was significantly higher for the 2D group than for the 3D group (13,901.82 ± 5549.69 vs 4682.82 ± 1950.64, p < 0.001). The use of the DynaCT angiographic reconstruction technique to guide BPA required a lower dose of contrast agent (225.22 ± 48.70 vs 292.73 ± 76.82 mL, p = 0.013) and less radiation exposure.The use of DynaCT angiographic reconstruction guidance in patients undergoing BPA is feasible and accurate. Images of DynaCT angiographic reconstruction may be beneficial for optimizing the operative process in BPA with reduced radiation exposure.• BPA guidance by DynaCT angiographic reconstruction is feasible and accurate. • DynaCT angiographic reconstruction may be beneficial for optimizing the operative process. • DynaCT angiographic reconstruction can reduce patient radiation dose due to multi-times of BPA sessions.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (17)
CITATIONS (12)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....