Incidence of infectious complications following ultrasound-guided percutaneous musculoskeletal interventions with the use of an uncovered transducer footprint
03 medical and health sciences
0302 clinical medicine
Incidence
Transducers
Humans
Ultrasonography, Interventional
Anti-Bacterial Agents
Retrospective Studies
DOI:
10.1007/s00330-022-08849-6
Publication Date:
2022-05-17T04:02:51Z
AUTHORS (7)
ABSTRACT
To determine the incidence of infectious complications following ultrasound-guided musculoskeletal interventions performed with a disinfected uncovered ultrasound transducer footprint.Electronic medical records of all patients who underwent an ultrasound-guided musculoskeletal procedure (including injection, calcific lavage, or ganglion cyst aspiration) performed by any of the 14 interventional musculoskeletal radiologists at our institution between January 2013 and December 2018 were retrospectively reviewed to identify procedure site infections. Biopsies and joint aspirations were excluded. The procedures were performed using a disinfected uncovered transducer footprint. First, an automated chart review identified cases with (1) positive answers to the nurse's post-procedure call, (2) an International Classification of Diseases (ICD) diagnostic code related to a musculoskeletal infection, or (3) an antibiotic prescription within 30 days post-procedure. Then, these cases were manually reviewed for evidence of procedure site infection.In total, 6511 procedures were included. The automated chart review identified 3 procedures (2 patients) in which post-procedural fever was reported during the nurse's post-procedure call, 33 procedures (28 patients) with an ICD code for a musculoskeletal infection, and 220 procedures (216 patients) with an antibiotic prescription within 30 post-procedural days. The manual chart review of these patients revealed no cases of confirmed infection and 1 case (0.015%) of possible site infection.The incidence of infectious complications after an ultrasound-guided musculoskeletal procedure performed with an uncovered transducer footprint is extremely low. This information allows radiologists to counsel their patients more precisely when obtaining informed consent.• Infectious complications after ultrasound-guided musculoskeletal procedures performed with a disinfected uncovered transducer footprint are extremely rare.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (28)
CITATIONS (3)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....