Seizure Onset Zone Localization from Ictal High-Density EEG in Refractory Focal Epilepsy
Adult
Male
Technology and Engineering
INTERICTAL SPIKES
Neuroimaging
HIGH-RESOLUTION EEG
Functional connectivity
03 medical and health sciences
0302 clinical medicine
SPARSE VOLUMETRIC PRIORS
Seizures
Medicine and Health Sciences
TEMPORAL-LOBE EPILEPSY
Humans
BRAIN
High-density electroencephalogram (hd-EEG)
Electrodes
Refractory epilepsy
Brain
DIPOLE-SOURCE LOCALIZATION
Electroencephalography
FUNCTIONAL CONNECTIVITY
info:eu-repo/classification/ddc/616.8
Middle Aged
NETWORKS
ddc:616.8
SOURCE RECONSTRUCTION
HEAD MODEL
Granger causality
Female
Epilepsies, Partial
Algorithms
EEG source imaging (ESI)
DOI:
10.1007/s10548-016-0537-8
Publication Date:
2016-11-17T04:41:02Z
AUTHORS (9)
ABSTRACT
Epilepsy surgery is the most efficient treatment option for patients with refractory epilepsy. Before surgery, it is of utmost importance to accurately delineate the seizure onset zone (SOZ). Non-invasive EEG is the most used neuroimaging technique to diagnose epilepsy, but it is hard to localize the SOZ from EEG due to its low spatial resolution and because epilepsy is a network disease, with several brain regions becoming active during a seizure. In this work, we propose and validate an approach based on EEG source imaging (ESI) combined with functional connectivity analysis to overcome these problems. We considered both simulations and real data of patients. Ictal epochs of 204-channel EEG and subsets down to 32 channels were analyzed. ESI was done using realistic head models and LORETA was used as inverse technique. The connectivity pattern between the reconstructed sources was calculated, and the source with the highest number of outgoing connections was selected as SOZ. We compared this algorithm with a more straightforward approach, i.e. selecting the source with the highest power after ESI as the SOZ. We found that functional connectivity analysis estimated the SOZ consistently closer to the simulated EZ/RZ than localization based on maximal power. Performance, however, decreased when 128 electrodes or less were used, especially in the realistic data. The results show the added value of functional connectivity analysis for SOZ localization, when the EEG is obtained with a high-density setup. Next to this, the method can potentially be used as objective tool in clinical settings.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (63)
CITATIONS (57)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....