Echocardiography and magnetic resonance imaging based strain analysis of functional single ventricles: a study of intra- and inter-modality reproducibility
Heart Defects, Congenital
Male
Observer Variation
Adolescent
Heart Ventricles
Reproducibility of Results
Fontan Procedure
Magnetic Resonance Imaging
Myocardial Contraction
Young Adult
03 medical and health sciences
0302 clinical medicine
Echocardiography
Predictive Value of Tests
Humans
Ventricular Function
Female
Stress, Mechanical
Child
Boston
Retrospective Studies
DOI:
10.1007/s10554-016-0882-4
Publication Date:
2016-04-18T11:16:59Z
AUTHORS (5)
ABSTRACT
The purpose of this study was to measure reproducibility in strain measurements by echocardiography and cardiac magnetic resonance imaging (CMR) in functional single ventricles in the Fontan circulation. Fontan echocardiograms and CMRs between 1/2005 and 6/2013 were analyzed retrospectively. Patients were included if studies occurred <1 year apart and without interim catheter-based or surgical intervention. Global peak systolic circumferential (GCS) and longitudinal (GLS) strain, and strain rates (GCSR and GLSR) were measured by speckle or feature tracking (echocardiogram vs. CMR) using commercial software. 134 study pairs were identified; 74 with dominant left and 60 with dominant right ventricles. Agreement for strain and strain rate between echocardiogram and CMR was modest for circumferential measurements, concordance correlation coefficient (Rc) = 0.56 for GCS, 0.44 for GCSR; and low for longitudinal measurements, Rc = 0.34 for GLS, and 0.27 for GLSR. There was good inter-observer agreement (n = 30) for strain measurements by echocardiogram and CMR (echocardiogram GCS Rc = 0.84, echocardiogram GLS Rc = 0.79, CMR GCS Rc = 0.94, CMR GLS Rc = 0.75). Inter-observer agreement for strain rate was slightly lower (echocardiogram GCSR Rc = 0.79, echocardiogram GLSR Rc = 0.73, CMR GCSR Rc = 0.93, CMR GLSR Rc = 0.54). Coefficients for intra-observer agreement for these variables were similar to inter-observer agreement. In conclusion, intra-modality reproducibility for strain assessment in functional single ventricles in the Fontan circulation is high, measured both by echocardiography and CMR; inter-modality reproducibility, however, is modest. These findings caution against mixing values from multiple modalities in the long-term assessment of patient health in this population.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (23)
CITATIONS (29)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....