Cooling process of iron ore pellets in an annular cooler

0202 electrical engineering, electronic engineering, information engineering 02 engineering and technology
DOI: 10.1007/s12613-011-0435-8 Publication Date: 2011-05-28T02:29:32Z
ABSTRACT
A 3-D mathematical model was presented for the cooling process of iron ore pellets based on the laws of mass, momentum, and heat transfer. The flow, pressure, and temperature fields were obtained by numerical simulation with the commercial software FLUENT. In order to verify the model, a mass and energy balance field test was systematically carried out on an annular cooler in Shougang Mining Company. The maximum relative errors of temperature, pressure, and velocity between computational and testing results are 2.87%, −8.11%, and 7.14%, respectively, indicating the validity of the model. Further, the effects of process parameters, such as pellet diameter, bed thickness, air velocity, and temperature, on the pellet bed temperature profiles were studied.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (17)
CITATIONS (11)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....