Effect of particle size on uranium bioleaching in column reactors from a low-grade uranium ore
Uranium ore
Uranium oxide
DOI:
10.1016/j.biortech.2019.02.065
Publication Date:
2019-02-15T03:51:31Z
AUTHORS (7)
ABSTRACT
This study evaluated the effectiveness of ore particle size on column bioleaching from low-grade uranium ore using an indigenous Acidithiobacillus ferrooxidans, isolated from local uranium ore. The uranium content was 0.033% by weight and ore particle size was crushed to <50 mm, <30 mm, and <15 mm. The additive content of sulfuric acid 5 g/L, Fe3+ dosage of 5.0 g/L, spray strength of 2.57 L/(h·m2) and temperature of 25 °C were controlled. After 150 days of leaching, acid consumption amounted to 2.73 g H2SO4 per kg ore, the obtained maximum uranium extraction was 64.85% with the ore particle size of <15 mm. The results showed that a smaller particle size ore had a higher uranium extraction and that an economic uranium extraction can be obtained by correctly controlling the ore granularity.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (44)
CITATIONS (37)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB