Data to support the assessment of the energy efficiency estimation methods on induction motors considering real-time monitoring.
Science (General)
Harmonics
Computer applications to medicine. Medical informatics
R858-859.7
02 engineering and technology
7. Clean energy
Motor efficiency estimation methods
Q1-390
Energy efficiency
Engineering
Induction motors
0202 electrical engineering, electronic engineering, information engineering
Voltage unbalance
DOI:
10.1016/j.dib.2020.105512
Publication Date:
2020-04-23T11:38:26Z
AUTHORS (4)
ABSTRACT
The data presented in this article was used to assess and compare the most important methods estimate efficiency during operation of induction motors at different loads power supply conditions. experiment developed a test bench including three-phase motor 1.1 kW (De Lorenzo DL 1021). In addition, an adjustable voltage source, variable-frequency drive, resistor, magnetic powder brake control unit regulate load were experiments. A quality energy analyzer (Fluke 435 series 6) measure electric variables Moreover, for mechanical measures, sensors 1054TT) 1019P) used. total, 11 factors measured conditions, balanced sinusoidal voltage, harmonic unbalanced voltage. total 10 measures taken each factor condition. paper can be useful development evaluation new estimation motors, considering conditions factors. it serve impact on motors. is related manuscript "Assessment real-time monitoring" [1].