Longitudinal Changes in Right Ventricular Function in Tetralogy of Fallot in the Initial Years after Surgical Repair
Male
Time Factors
Ventricular Dysfunction, Right
Age Factors
Infant, Newborn
Infant
Prognosis
Echocardiography, Doppler
03 medical and health sciences
0302 clinical medicine
Case-Control Studies
Child, Preschool
Preoperative Care
Tetralogy of Fallot
Ventricular Function, Right
Humans
Female
Cardiac Surgical Procedures
Monitoring, Physiologic
Retrospective Studies
DOI:
10.1016/j.echo.2018.02.013
Publication Date:
2018-04-04T11:57:41Z
AUTHORS (8)
ABSTRACT
Right ventricular (RV) dysfunction is associated with adverse long-term outcomes in patients with tetralogy of Fallot. Little is known about RV function in the first years after surgical repair. The aim of this study was to investigate perioperative changes in myocardial deformation using global longitudinal strain.A retrospective analysis of patients with surgically repaired tetralogy of Fallot was performed. Global longitudinal peak systolic RV strain was measured on early postoperative echocardiograms, two subsequent postoperative echocardiograms through 2 years postoperatively, and preoperative echocardiograms, when available. Preoperative and late follow-up strain was compared with strain in 0- to 8-month-old and 1- to 4-year-old control subjects, respectively.Forty-seven patients were included. Compared with postoperative strain (7 ± 7 days postoperatively), strain at follow-up 1 (8.3 ± 4 months postoperatively) was significantly improved (-12.3 ± 3.3% vs -18.8 ± 2.5%, P < .001), with no additional improvement 23.2 ± 6 months postoperatively (-18.8 ± 2.5% vs -19.8 ± 3.1%, P = .12). Postoperative strain was worse than preoperative strain (n = 25, -12.5 ± 3.6% vs -18.4 ± 2.9%, P < .001). Compared with control subjects, preoperative strain was similar (-19.3 ± 3.8% vs -18.4 ± 2.9%, P = .30), though late follow-up strain was significantly worse (-27.7 ± 2.8% vs -19.8 ± 3.1%, P < .001).RV global longitudinal strain worsens in the early postoperative period following surgical repair of tetralogy of Fallot but recovers through 2 postoperative years. Despite recovery to preoperative values, the presence of RV dysfunction compared with control subjects suggests that long-term dysfunction may begin early. The trajectory of RV dysfunction through the later years needs further study.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (22)
CITATIONS (25)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....