The intra-observer reproducibility of cardiovascular magnetic resonance myocardial feature tracking strain assessment is independent of field strength
Medicine(all)
Male
Observer Variation
571
Heart Ventricles
610
Magnetic Resonance Imaging, Cine
Reproducibility of Results
Radiation Dosage
Sensitivity and Specificity
Pattern Recognition, Automated
Young Adult
03 medical and health sciences
Magnetic Fields
0302 clinical medicine
RC666-701
Poster Presentation
Image Interpretation, Computer-Assisted
Diseases of the circulatory (Cardiovascular) system
Elasticity Imaging Techniques
Humans
Ventricular Function
Female
DOI:
10.1016/j.ejrad.2012.11.012
Publication Date:
2012-12-11T20:01:20Z
AUTHORS (11)
ABSTRACT
Cardiovascular magnetic resonance myocardial feature tracking (CMR-FT) is a promising novel method for quantification of myocardial wall mechanics from standard steady-state free precession (SSFP) images. We sought to determine whether magnetic field strength affects the intra-observer reproducibility of CMR-FT strain analysis.We studied 2 groups, each consisting of 10 healthy subjects, at 1.5 T or 3T Analysis was performed at baseline and after 4 weeks using dedicated CMR-FT prototype software (Tomtec, Germany) to analyze standard SSFP cine images. Right ventricular (RV) and left ventricular (LV) longitudinal strain (Ell(RV) and Ell(LV)) and LV long-axis radial strain (Err(LAX)) were derived from the 4-chamber cine, and LV short-axis circumferential and radial strains (Ecc(SAX), Err(SAX)) from the short-axis orientation. Strain parameters were assessed together with LV ejection fraction (EF) and volumes. Intra-observer reproducibility was determined by comparing the first and the second analysis in both groups.In all volunteers resting strain parameters were successfully derived from the SSFP images. There was no difference in strain parameters, volumes and EF between field strengths (p>0.05). In general Ecc(SAX) was the most reproducible strain parameter as determined by the coefficient of variation (CV) at 1.5 T (CV 13.3% and 46% global and segmental respectively) and 3T (CV 17.2% and 31.1% global and segmental respectively). The least reproducible parameter was Ell(RV) (CV 1.5 T 28.7% and 53.2%; 3T 43.5% and 63.3% global and segmental respectively).CMR-FT results are similar with reasonable intra-observer reproducibility in different groups of volunteers at 1.5 T and 3T. CMR-FT is a promising novel technique and our data indicate that results might be transferable between field strengths. However there is a considerable amount of segmental variability indicating that further refinements are needed before CMR-FT can be fully established in clinical routine for quantitative assessment of wall mechanics and strain.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (24)
CITATIONS (116)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....