Customizable modification of banding with external stenting for arteriovenous fistula flow reduction

Innovative technique RD1-811 FRAME AVF 03 medical and health sciences 0302 clinical medicine Banding RC666-701 Diseases of the circulatory (Cardiovascular) system High flow Surgery Flow reduction
DOI: 10.1016/j.jvscit.2022.01.003 Publication Date: 2022-01-27T07:12:10Z
ABSTRACT
We performed a single-center retrospective study of prospectively collected data for all patients who had flow reduction surgery with FRAME FR between November 2020 and January 2021. Ten patients had arteriovenous fistula flow reduction surgery with this technique. One patient had a distal fistula, whereas nine were within the cubital fossa. In nine patients the device was applied over the postanastomotic arteriovenous fistula outflow vein and in one in the preanastomotic radial artery. Technical success was achieved in all patients with a median flow reduction from 2150 to 825 mL/min. There were no wound or device-specific complications.