Multi-channel whole-head OPM-MEG: Helmet design and a comparison with a conventional system
Adult
Male
0301 basic medicine
MEG
Functional Neuroimaging
OPM
Beta
Brain
Magnetoencephalography
Neurosciences. Biological psychiatry. Neuropsychiatry
Optically pumped magnetometer
Equipment Design
Article
Young Adult
03 medical and health sciences
0302 clinical medicine
Humans
Female
Head Protective Devices
Gamma
RC321-571
DOI:
10.1016/j.neuroimage.2020.116995
Publication Date:
2020-05-29T15:34:48Z
AUTHORS (14)
ABSTRACT
ABSTRACTMagnetoencephalography (MEG) is a powerful technique for functional neuroimaging, offering a non-invasive window on brain electrophysiology. MEG systems have traditionally been based on cryogenic sensors which detect the small extracranial magnetic fields generated by synchronised current in neuronal assemblies, however such systems have fundamental limitations. In recent years quantum-enabled devices, called optically-pumped magnetometers (OPMs), have promised to lift those restrictions, offering an adaptable, motion-robust MEG device, with improved data quality, at reduced cost. However, OPM-MEG remains a nascent technology, and whilst viable systems exist, most employ small numbers of sensors sited above targeted brain regions. Here, building on previous work, we construct a wearable OPM-MEG system with ‘whole-head’ coverage based upon commercially available OPMs, and test its capabilities to measure alpha, beta and gamma oscillations. We design two methods for OPM mounting; a flexible (EEG-like) cap and rigid (additively-manufactured) helmet. Whilst both designs allow for high quality data to be collected, we argue that the rigid helmet offers a more robust option with significant advantages for reconstruction of field data into 3D images of changes in neuronal current. Using repeat measurements in two participants, we show signal detection for our device to be highly robust. Moreover, via application of source-space modelling, we show that, despite having 5 times fewer sensors, our system exhibits comparable performance to an established cryogenic MEG device. While significant challenges still remain, these developments provide further evidence that OPM-MEG is likely to facilitate a step change for functional neuroimaging.HIGHLIGHTSA 49-channel whole-head OPM-MEG system is constructedSystem evaluated via repeat measurements of alpha, beta and gamma oscillationsTwo OPM-helmet designs are contrasted, a flexible (EEG-like) cap and a rigid helmetThe rigid helmet offers significant advantages for a viable OPM-MEG device49-channel OPM-MEG offers performance comparable to established cryogenic devices
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (66)
CITATIONS (222)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....