Less is more: balancing noise reduction and data retention in fMRI with data-driven scrubbing

FOS: Computer and information sciences Brain Mapping Reproducibility of Results Brain Neurosciences. Biological psychiatry. Neuropsychiatry Statistics - Applications Magnetic Resonance Imaging Article Motion 03 medical and health sciences 0302 clinical medicine Image Processing, Computer-Assisted Humans Applications (stat.AP) Artifacts RC321-571
DOI: 10.1016/j.neuroimage.2023.119972 Publication Date: 2023-02-25T03:37:27Z
ABSTRACT
Artifacts in functional MRI (fMRI) data cause deviations from common distributional assumptions, introduce spatial and temporal outliers, and reduce the signal-to-noise ratio of the data -- all of which can have negative consequences for downstream statistical analysis. Scrubbing is a technique for excluding fMRI volumes thought to be contaminated by artifacts and generally comes in two flavors. Motion scrubbing based on subject head motion-derived measures is popular but suffers from a number of drawbacks, especially high rates of censoring of individual volumes and entire subjects. Alternatively, data-driven scrubbing methods like DVARS are based on observed noise in the processed fMRI timeseries and may avoid some of these issues. Here we propose "projection scrubbing", a novel data-driven scrubbing method based on a statistical outlier detection framework and strategic dimension reduction, including independent component analysis (ICA), to isolate artifactual variation. We undertake a comprehensive comparison of motion scrubbing with data-driven projection scrubbing and DVARS. We argue that an appropriate metric for the success of scrubbing is maximal data retention subject to reasonable performance on typical benchmarks of functional connectivity. We find that stringent motion scrubbing yields worsened validity, worsened reliability, and produced small improvements to fingerprinting. Meanwhile, data-driven scrubbing methods tend to yield greater improvements to fingerprinting while not generally worsening validity or reliability. Importantly, however, data-driven scrubbing excludes a fraction of the number of volumes or entire sessions compared to motion scrubbing. The ability of data-driven fMRI scrubbing to improve data retention without negatively impacting the quality of downstream analysis has major implications for sample sizes in population neuroscience research.<br/>74 pages<br/>
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (89)
CITATIONS (13)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....