Performance of the diamond-based beam-loss monitor system of Belle II

Radiation monitoring Physics - Instrumentation and Detectors FOS: Physical sciences Diamond sensor Instrumentation and Detectors (physics.ins-det) sCVD diamond sensor; Beam-loss monitoring; Accelerator interlocks; Diamond sensor; Radiation monitoring; Accelerator interlocks; Beam-loss monitoring; sCVD diamond sensor 01 natural sciences Accelerator interlock 0103 physical sciences Beam-loss monitoring sCVD diamond sensor
DOI: 10.1016/j.nima.2021.165157 Publication Date: 2021-02-18T03:03:43Z
ABSTRACT
We designed, constructed and have been operating a system based on single-crystal synthetic diamond sensors, to monitor the beam losses at the interaction region of the SuperKEKB asymmetric-energy electron-positron collider. The system records the radiation dose-rates in positions close to the inner detectors of the Belle II experiment, and protects both the detector and accelerator components against destructive beam losses, by participating in the beam-abort system. It also provides complementary information for the dedicated studies of beam-related backgrounds. We describe the performance of the system during the commissioning of the accelerator and during the first physics data taking.