Fully guided implant surgery using Magnetic Resonance Imaging – An in vitro study on accuracy in human mandibles
Dental Implants
Dental Implantation, Endosseous
Kernspintomografie
610
Mandible
Cone-Beam Computed Tomography
Magnetic Resonance Imaging
Patient Care Planning
computer-aided design
03 medical and health sciences
Imaging, Three-Dimensional
0302 clinical medicine
Surgery, Computer-Assisted
virtual implant planning
guided implant surgery
Computer-Aided Design
Humans
magnetic resonance imaging
600 Technik, Medizin, angewandte Wissenschaften::610 Medizin und Gesundheit::610 Medizin und Gesundheit
DOI:
10.1111/clr.13622
Publication Date:
2020-05-27T20:30:11Z
AUTHORS (6)
ABSTRACT
AbstractObjectivesThe objective of this in vitro study was to assess the accuracy of fully guided implant placement following virtual implant planning based on MRI.Material and MethodsSixteen human cadaver hemimandibles with single missing teeth (n = 3), partially edentulous (n = 6) and edentulous situations (n = 7) were imaged using MRI. MRI and optical scans obtained with an intraoral scanner, were imported into an implant planning software. Virtual prosthetic and implant planning were performed regarding hard‐ and soft‐tissue anatomy. Drill guides were manufactured, and fully guided implant placement was performed. Buccal and lingual bone and implant nerve distance were measured by three examiners in preoperative MRI and postoperative CBCT. The implant position was assessed using a software for deviation of implant positions displayed in CBCT and optical scans, respectively.ResultsMRI displayed relevant structures for implant planning such as cortical and cancellous bone, inferior alveolar nerve and neighboring teeth. Implant planning, CAD/CAM of drill guides and guided implant placement were performed. Deviations between planned and actual implant positions in postoperative CBCT and optical scans were 1.34 mm (SD 0.84 mm) and 1.03 mm (SD 0.46 mm) at implant shoulder; 1.41 mm (SD 0.88 mm) and 1.28 mm (SD 0.52 mm) at implant apex, and 4.84° (SD 3.18°) and 4.21° (SD 2.01°). Measurements in preoperative MRI and postoperative CBCT confirmed the compliance with minimum distances of implants to anatomical structures.ConclusionsRelevant anatomical structures for imaging diagnostics in implant dentistry are displayed with MRI. The accuracy of MRI‐based fully guided implant placement in vitro is comparable to the workflow using CBCT.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (33)
CITATIONS (11)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....