Laboratory evaluation of immunochromatographic rapid diagnostic tests for cholera in Haiti

Bacterial Diseases Diarrhea Materials by Structure Science Materials Science Bacterial Cultures Gastroenterology and Hepatology Pathology and Laboratory Medicine Crystals Microbiology Geographical locations Chromatography, Affinity 03 medical and health sciences Signs and Symptoms 0302 clinical medicine Cholera Diagnostic Medicine Caries Vibrio Cholerae Medicine and Health Sciences Humans Microbial Pathogens Vibrio Retrospective Studies Caribbean Bacteria Q Organisms R Biology and Life Sciences Microbial Cultures Tropical Diseases Haiti Bacterial Pathogens 3. Good health Infectious Diseases Medical Microbiology Physical Sciences North America Medicine Biological Cultures Reagent Kits, Diagnostic Pathogens People and places Neglected Tropical Diseases Research Article
DOI: 10.1371/journal.pone.0186710 Publication Date: 2017-11-01T16:43:00Z
ABSTRACT
Rapid diagnostic tests (RDT) for cholera are promising tools for detecting cholera in areas with limited laboratory infrastructure. However, evidence on the characteristics of the many available RDTs is scarce, and their use has been limited by suboptimal performance. We evaluated the performance characteristics of three cholera RDTs from Span Diagnostics, Artron Laboratories, and Standard Diagnostics in a regional laboratory in Haiti.We retrospectively reviewed records from May 2014 to October 2015 of a laboratory-based surveillance program for Vibrio cholerae at Hôpital Saint-Nicolas in Saint-Marc, Haiti. We compared the results of 511 Crystal VC, 129 Artron and 451 SD Bioline RDTs to bacterial culture as the gold standard. Of 905 cultures, 477 (52.7%) were positive for V. cholerae O1, of which 27.7% were serotype Inaba. No cultures grew V. cholerae O139. Sensitivity and specificity of Crystal VC were 98.6% (95%CI: 96.5%-99.6%) and 71.1% (95%CI: 64.7%-76.9%), respectively. Artron demonstrated a sensitivity of 98.6% (95%CI: 92.7%-100%) and specificity of 69.1% (95%CI: 55.2%-80.9%). SD Bioline demonstrated a sensitivity of 81.1% (95%CI: 75.6%-85.8%) and specificity of 92.8% (95%CI: 88.4%-95.9%). Crystal VC and Artron frequently showed false positive O139 bands, whereas none were seen with SD Bioline.There is significant variation in the performance of different cholera diagnostic RDTs. Artron and Crystal VC RDTs have high sensitivity and low specificity, while SD Bioline RDT has low to moderate sensitivity and high specificity when performed by laboratory technicians in Haiti. Study limitations included its retrospective design. The suboptimal characteristics of these tests limit their use as clinical point-of-care tests; however, they may be useful in outbreak response, surveillance, and research in resource-limited settings.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (26)
CITATIONS (20)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....