A Liquid Well Barrier Element for Temporary Plug & Abandonment Operations: A Breakthrough Approach
Abandonment (legal)
Spark plug
DOI:
10.20944/preprints202408.0572.v1
Publication Date:
2024-08-14T07:55:45Z
AUTHORS (8)
ABSTRACT
Plug and abandonment (P&A) operations demand valuable time resources with operational procedures materials to establish the well barrier element. This study proposes use of a water-based fluid as liquid element for temporary abandonment, based on esti-mates its lifespan survival probability downhole conditions acquired through acceler-ated life tests. For that, formulation was tested exposed 95, 110, 140 150°C, intervals ranging from 1 10 days. After temperature exposure, prop-erties were verified failure detected by accounting any deterioration in rheological parameters and/or substantial increase filtrate volume. Statistical analysis data performed R software using Weibull Model, average estimated P&A temperatures. The results obtained demonstrates that degradation only observed 150°C is mostly related CMC deterioration. reliability metrics shows until 80°C promising alternative no need monitoring. higher temperatures, theses should be considered define maximum operation requirements monitoring management design.