Haemocompatibility evaluation of DLC- and SiC-coated surfaces
Blood Platelets
570
Thrombin generation
Diamond-like carbon coating
Surface Properties
Complement convertase attachment
Carbon Compounds, Inorganic
plasma depo- sition
610
[PHYS.MECA.MSMECA] Physics [physics]/Mechanics [physics]/Materials and structures in mechanics [physics.class-ph]
Biocompatible Materials
[SPI.MECA.MSMECA]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Materials and structures in mechanics [physics.class-ph]
ddc:500.2
Complement C3-C5 Convertases
02 engineering and technology
info:eu-repo/classification/ddc/500.2
Platelet Adhesiveness
Coated Materials, Biocompatible
info:eu-repo/classification/ddc/616
Materials Testing
Spectroscopy, Fourier Transform Infrared
[SPI.MECA.MSMECA] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Materials and structures in mechanics [physics.class-ph]
Humans
ddc:616
Silicon Compounds
Thrombin
[PHYS.MECA.MSMECA]Physics [physics]/Mechanics [physics]/Materials and structures in mechanics [physics.class-ph]
Platelet Activation
complement convertase attachment
Carbon
complement convertase attachment.
thrombin generation
Enzyme Induction
Microscopy, Electron, Scanning
Plasma deposition
platelet adhesion
Diamond
0210 nano-technology
DOI:
10.22203/ecm.v005a02
Publication Date:
2016-11-21T07:06:25Z
AUTHORS (8)
ABSTRACT
Diamond-like carbon (DLC) and silicon carbide (SiC) coatings are attractive because of low friction coefficient, high hardness, chemical inertness smooth finish, which they provide to biomedical devices. Silicon wafers (Si(waf)) silicone rubber (Si(rub)) plates were coated using plasma-enhanced vapour deposition (PE-CVD) techniques. This article describes: 1- the characterization modified surfaces attenuated total reflection-Fourier transform infrared spectroscopy (ATR/FTIR) contact angle measurements, 2- results three in-vitro haemocompatibility assays. Coated compared uncoated materials various substrates such as polymethylmethacrylate (PMMA), polyethylene (LDPE), polydimethylsiloxane (PDMS) medical steel (MS). Thrombin generation, blood platelet adhesion complement convertase activity tests revealed following classification, from most least heamocompatible surface: Si(rub)/ DLC-Si(rub)/ DLC-Si(waf)/ LDPE/ PDMS/ SiC-Si(waf)/ Si(waf)/ PMMA/ MS. The DLC coating delayed clotting time, tended inhibit activation, whereas SiC-coated wafer can be considered thrombogenic. study has taken into account events activation: coagulation, activation inflammation. response those is an indicator in vitro different it allows us select biomaterials for further vivo contacting investigations.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (0)
CITATIONS (69)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....