Haemocompatibility evaluation of DLC- and SiC-coated surfaces

Blood Platelets 570 Thrombin generation Diamond-like carbon coating Surface Properties Complement convertase attachment Carbon Compounds, Inorganic plasma depo- sition 610 [PHYS.MECA.MSMECA] Physics [physics]/Mechanics [physics]/Materials and structures in mechanics [physics.class-ph] Biocompatible Materials [SPI.MECA.MSMECA]Engineering Sciences [physics]/Mechanics [physics.med-ph]/Materials and structures in mechanics [physics.class-ph] ddc:500.2 Complement C3-C5 Convertases 02 engineering and technology info:eu-repo/classification/ddc/500.2 Platelet Adhesiveness Coated Materials, Biocompatible info:eu-repo/classification/ddc/616 Materials Testing Spectroscopy, Fourier Transform Infrared [SPI.MECA.MSMECA] Engineering Sciences [physics]/Mechanics [physics.med-ph]/Materials and structures in mechanics [physics.class-ph] Humans ddc:616 Silicon Compounds Thrombin [PHYS.MECA.MSMECA]Physics [physics]/Mechanics [physics]/Materials and structures in mechanics [physics.class-ph] Platelet Activation complement convertase attachment Carbon complement convertase attachment. thrombin generation Enzyme Induction Microscopy, Electron, Scanning Plasma deposition platelet adhesion Diamond 0210 nano-technology
DOI: 10.22203/ecm.v005a02 Publication Date: 2016-11-21T07:06:25Z
ABSTRACT
Diamond-like carbon (DLC) and silicon carbide (SiC) coatings are attractive because of low friction coefficient, high hardness, chemical inertness smooth finish, which they provide to biomedical devices. Silicon wafers (Si(waf)) silicone rubber (Si(rub)) plates were coated using plasma-enhanced vapour deposition (PE-CVD) techniques. This article describes: 1- the characterization modified surfaces attenuated total reflection-Fourier transform infrared spectroscopy (ATR/FTIR) contact angle measurements, 2- results three in-vitro haemocompatibility assays. Coated compared uncoated materials various substrates such as polymethylmethacrylate (PMMA), polyethylene (LDPE), polydimethylsiloxane (PDMS) medical steel (MS). Thrombin generation, blood platelet adhesion complement convertase activity tests revealed following classification, from most least heamocompatible surface: Si(rub)/ DLC-Si(rub)/ DLC-Si(waf)/ LDPE/ PDMS/ SiC-Si(waf)/ Si(waf)/ PMMA/ MS. The DLC coating delayed clotting time, tended inhibit activation, whereas SiC-coated wafer can be considered thrombogenic. study has taken into account events activation: coagulation, activation inflammation. response those is an indicator in vitro different it allows us select biomaterials for further vivo contacting investigations.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (0)
CITATIONS (69)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....