Dimensioning of Subsynchronous Cascade for Speed Regulation of Two-Motors 6kv Conveyer Drives
Dimensioning
DOI:
10.5281/zenodo.1334134
Publication Date:
2011-03-22
AUTHORS (3)
ABSTRACT
One way for optimum loading of overdimensioning
conveyers is speed (capacity) decrement, with attention for
production capabilities and demands. At conveyers which drives with
three phase slip-ring induction motor, technically reasonable solution
for conveyer (driving motors) regulation using constant
torque subsynchronous cascade static semiconductor converter
and transformer energy reversion to the power network. In the
paper described mathematical model parameter calculation of
two-motors 6 kV cascade. It also demonstrated
that applying this gave several good properties, foremost
in electrical saving, in improving other energy
indexes, finally that results cost reduction complete
electrical motor drive.