D. Jewett

ORCID: 0000-0001-7767-3658
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Electrical Fault Detection and Protection
  • Lightning and Electromagnetic Phenomena
  • Power Systems Fault Detection
  • Thermal Analysis in Power Transmission
  • Electrical Contact Performance and Analysis
  • HVDC Systems and Fault Protection
  • Electromagnetic Compatibility and Noise Suppression
  • Magnetic Properties and Applications
  • Electromagnetic Launch and Propulsion Technology
  • High-Voltage Power Transmission Systems

University of New Brunswick
2022-2023

This paper experimentally evaluates responses of ground fault protection for synchronous generators, which are grounded using frequency-selective grounding. Frequency-selective grounding is designed to provide a low impedance path (similar solid grounding) high frequency zero-sequence current components. system also provides an similar low-resistance The frequency-dependent equivalent can affect potential and current, typically used as inputs protective relays. Effects on evaluated 7.5 kVA...

10.1109/tia.2022.3233558 article EN IEEE Transactions on Industry Applications 2023-01-02

This paper presents performance assessment of ground fault protection for systems supplied by a transformer, which has frequency-selective grounding. Frequency-selective grounding is new system that designed to act as solid-grounding high frequency currents, and low resistance-grounding currents. composed from parallel <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$R-C$</tex-math></inline-formula> circuit...

10.1109/tia.2022.3233560 article EN IEEE Transactions on Industry Applications 2023-01-04

Geomagnetically induced currents (GICs) flow through grounding circuits into power systems, when triggered by geomagnetic disturbances. Power transformers (with connections) are the primary path for GIC flows systems. The of GICs a transformer can create adverse impacts on its operation, including large increases in reactive demands and significant harmonic distortions side currents. This article presents case studies analyses transformers. Presented conducted two with different core types,...

10.1109/tia.2023.3287471 article EN IEEE Transactions on Industry Applications 2023-06-20

In this article, experimental performance assessment and comparison are presented for solid, low impedance, high frequency-selective, isolated grounding (IG) systems. The typical design of a system (for medium voltage generation, transmission, distribution systems) is based on selecting an impedance ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\bar{Z}_{G}$</tex-math></inline-formula> ), which used to...

10.1109/tia.2022.3189614 article EN IEEE Transactions on Industry Applications 2022-07-11

This article presents a performance comparison of the solid, low impedance, high frequency-selective, and isolated grounding systems. A system (for any power component) is designed as an impedance ( <inline-formula xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink"><tex-math notation="LaTeX">$\bar{Z}_{G}$</tex-math></inline-formula> ) that connects neutral point to ground. The constructed using combination...

10.1109/tia.2022.3190261 article EN IEEE Transactions on Industry Applications 2022-07-13

The selection of a grounding configuration and design impedance is vital importance for the stability functionality power systems, including industrial commercial systems. These key aspects systems have been subject various standards, codes, recommended practices. In this article, review, modeling, analysis different system designs are provided. discussed in article compared terms ground potential, currents, overvoltage during faults. implemented components order to assess their capabilities...

10.1109/tia.2022.3186290 article EN IEEE Transactions on Industry Applications 2022-06-24

Geomagnetically induced currents (GICs) flow through grounding circuits into power systems, when triggered by geomagnetic disturbances. Power transformers (with connections) are one of the common paths for GIC flows systems. The GICs a transformer can create adverse impacts on its operation, including disruptions in reactive and significant harmonic distortions primary secondary side currents. This paper presents case studies analyzing distortion due to various levels transformers. Presented...

10.1109/icps57144.2023.10142106 article EN 2023-05-21

This paper presents a performance comparison of the solid, low impedance, high frequency-selective, and isolated grounding systems. A system (for any power component) is designed as an impedance (Z̄ <inf xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">G</inf> ) that connects neutral point to ground. The Z̄ constructed using combination R, L, C elements. values type (series or parallel) C, determine possible influence on ground currents potentials....

10.1109/icps54075.2022.9773920 article EN 2022-05-02

The selection of a grounding configuration and design impedance are vital importance for the stability functionality power systems, including industrial commercial systems. These key aspects systems have been subject various standards, codes, recommended practices. In this paper, review is provided methods procedures developed selecting designing in reviewed compared terms ground potential, currents (during fault non-fault conditions), overvoltage during asymmetrical faults, phase inversion....

10.1109/icps54075.2022.9773805 article EN 2022-05-02

This paper presents experimental results for performance tests of ground fault protection schemes applied to a frequency-selective grounded system supplied by single transformer. Frequency selective grounding systems are designed present low impedance (similar solid grounding) high frequency zero-sequence current components and like that low-impedance fundamental components. The variable the scheme can impact response in terms accuracy timing. laboratory setup includes 35kVa 3-phase source...

10.1109/ias54023.2022.9939836 article EN 2022 IEEE Industry Applications Society Annual Meeting (IAS) 2022-10-09

This paper experimentally evaluates responses of ground fault protection for synchronous generators, which are grounded using frequency-selective grounding. Frequency-selective grounding is designed to provide a low impedance path (similar solid grounding) high frequency zero-sequence current components. system also provides an similar low-resistance The frequency-dependent equivalent can affect potential and current, typically used as inputs protective relays. Effects on evaluated 7.5 kVA...

10.1109/ias54023.2022.9939677 article EN 2022 IEEE Industry Applications Society Annual Meeting (IAS) 2022-10-09

This paper presents experimental results for performance tests of ground fault protection schemes applied to a frequency-selective grounded system supplied by single transformer. Frequency selective grounding systems are designed present low impedance (similar solid grounding) high frequency zero-sequence current components and like that low-impedance fundamental components. The variable the scheme can impact response in terms accuracy timing. laboratory setup includes 35kVa 3-phase source...

10.1109/tia.2022.3190992 article EN IEEE Transactions on Industry Applications 2022-01-01

This paper experimentally evaluates responses of ground fault protection for synchronous generators, which are grounded using frequency-selective grounding. Frequency-selective grounding is designed to provide a low impedance path (similar solid grounding) high frequency zero-sequence current components. system also provides an similar low-resistance The frequency-dependent equivalent can affect potential and current, typically used as inputs protective relays. Effects on evaluated 7.5 kVA...

10.1109/tia.2022.3191041 article EN IEEE Transactions on Industry Applications 2022-01-01
Coming Soon ...