- Corneal Surgery and Treatments
- Ocular Surface and Contact Lens
- Corneal surgery and disorders
- Glaucoma and retinal disorders
- Ophthalmology and Visual Impairment Studies
- Intraocular Surgery and Lenses
- Ocular Infections and Treatments
- Ocular Oncology and Treatments
- Nasolacrimal Duct Obstruction Treatments
- Facial Rejuvenation and Surgery Techniques
- Genetic and rare skin diseases.
- Nonmelanoma Skin Cancer Studies
- Reconstructive Facial Surgery Techniques
- Retinal Diseases and Treatments
- Vascular Tumors and Angiosarcomas
- Dermatologic Treatments and Research
- Connexins and lens biology
- Tumors and Oncological Cases
- Heme Oxygenase-1 and Carbon Monoxide
- Metallurgy and Material Science
- Pediatric health and respiratory diseases
- Plasma Applications and Diagnostics
- Travel-related health issues
- Optical Wireless Communication Technologies
- Dental Anxiety and Anesthesia Techniques
Semnan University of Medical Sciences
2018-2024
Basir Eye Health Research Center
2017-2024
Iran University of Medical Sciences
2021
Farabi Hospital
2015-2019
Shahid Beheshti University of Medical Sciences
2014-2015
Baqiyatallah University of Medical Sciences
2014
Tehran University of Medical Sciences
2007
We evaluate the efficacy and safety of Keraring 355° intrastromal corneal ring segment (ICRS) implantation aided by PocketMaker microkeratome for correction keratoconus. Patients underwent ICRS insertion using mechanical dissection with completed 6 months follow-up. Uncorrected visual acuity (UCVA), best spectacle-corrected (BSCVA), refraction, topographic findings, safety, index, adverse events were reported six postoperatively. evaluated 15 eyes patients (12 men) a mean age 28.87 ± 6.94...
Conjunctival nevi (CN) are common benign ocular tumors. Given their low risk of malignancy, surgical removal is primarily requested by patients. Herein, we introduce Atmospheric Low-temperature Plasma (ALTP) as a novel noninvasive method for the CN.A clinical case series was conducted from 2020 to 2021 at Vision Health Ophthalmic Center in Tehran, Iran. CN one eyes seven patients treated. In all patients, benignity confirmed oncologists. The white handpiece Plexr device, which generates...
Background: Conjunctivochalasis (CCh) is a common bilateral conjunctival condition defined by loose, redundant folds, typically in the inferior bulbar conjunctiva. In recent years, various surgical procedures have been proposed to treat conjunctivochalasis that each has its own limitations. The aim of this study was evaluation quick treatment CCh using plasma, as noninvasive procedure, and effectiveness.Research design methods: study, six patients with grade 3 4 were evaluated non-randomized...
To evaluate long-term follow-up data on implantation of a full-ring intra-corneal implant (MyoRing) for management keratoconus.A total 40 keratoconic eyes 37 consecutive patients who had undergone MyoRing using the Pocket Maker microkeratome (Dioptex, GmbH, Linz, Austria) and completed 3 years appointments were included in this retrospective study. Uncorrected distance visual acuity (UDVA), corrected (CDVA), refraction keratometry (K) readings measured evaluated preoperatively, years,...
To evaluate the efficacy of topical cyclosporine A (tCsA) for treatment dry eye disease in patients suffering from chronic ocular complications mustard gas (MG) injury.This interventional case series included with MG injury severe despite receiving artificial tears and punctal plugs. Patients were administered tCsA 0.05% twice daily 3 months. Severity condition was evaluated by measuring tear osmolarity, surface index (OSDI), break-up time (TBUT), Schirmer's test at baseline end study.A...
Introducing a new technique to remove the conjunctival cyst using atmospheric low-temperature plasma (ALTP) and assessing its effectiveness.Five eyes with cysts were included in this study. The procedure was started by applying spot on highest point of cyst, then other spots spirally applied base debulk it. removed white handpiece generator device (Plexr, GMV s.r.l Grottaferrata, Italy). Refraction, visual acuity, intraocular pressure (IOP), contrast sensitivity (CS), aberrometry, dry eye...
Abstract Background Plasma medicine is an innovative research field focused on the application of atmospheric-pressure low-temperature plasmas (ALTP) for therapeutic purposes. Considering potentials plasma in ophthalmology, this study, we evaluated safety conjunctival tissue animal models 6 months. Methods Twelve adult male New Zealand albino rabbits were divided into four groups. The right eye each rabbit was chosen test and left considered as control. Experiments performed using Plexr...
<i>Background</i>: In recent years plasma medicine, played an important role in treating several ocular surface disorders. This study will introduce atmospheric low-temperature (ALTP) for removing the pinguecula. <i>Methods</i>: clinical case series, five eyes of patients (2 OD, 3 OS) with pinguecula were included. The removed and completely healed, using white handpiece generator device (Plexr, GMV s.r.l Grottaferrata, Italy). Refraction parameters, uncorrected distance visual acuity (UDVA)...
Purpose: To introduce a novel technique using PANIS method (Plasma assisted noninvasive surgery) in pterygium removal surgery with conjunctival rotation flap. Methods: Two patients (1 male, 1 Female) grade 3 and 4 of pterygium, based on SLIT2 grading system, underwent local anesthesia, removing tissue from cornea also all related subtenon. Then surgeon used residual conjunctiva to cover bare sclera rotational method. Fusion the border flaps nasal superior occurred by plasma spots. UCVA,...
This study aims to develop and assess an infrastructure using Python-based deep learning code for future diagnostic management purposes related dry eye disease (DED) utilizing smartphone images.
ABSTRACT Purpose To report complications after the implantation of Keraring 355° intrastromal corneal ring (ICR; Mediphacos, Belo Horizonte, Brazil) in keratoconic eyes using a Ziemer LDV femto- second laser (Ziemer AG, Switzerland) for channel creation. Materials and methods Five suffering from keratoconus underwent insertion pocket Intraoperative postoperative were recorded. Results While intraoperatively there no complication, postoperatively all cases showed severe side effects....
To customize clinical practice guidelines (CPGs) for cataract management in the Iranian population.First, four CPGs (American Academy of Ophthalmology 2006 and 2011, Royal College Ophthalmologists 2010, Canadian Ophthalmological Society 2008) were selected from a number available literature management. All recommendations these guidelines, together with their references, studied. Each recommendation was summarized 4 tables. The first table showed itself question components format along its...
Background: Several studies have reported plasma-assisted noninvasive surgery (PANIS method) as a simple, inexpensive, office-based, minimally invasive, effective technique for treating some ocular surface diseases.This study aims to explore the efficacy of this method occluding tear drainage system, temporary, in order treat dry eye disease.Methods: Study was undertaken six patients with moderate severe (Schirmer's test < 10 mm and TBUT sec).The inferior puncta were fused using white...
Purpose: Medical plasma application has been used in different fields recently. In this study, we assess the outcome of using plasma-assisted noninvasive surgery (PANIS) with amniotic membrane transplantation (AMT) pterygium surgical treatment. Methods: This clinical case series was conducted 4 patients primary grades 1, 2, and 3 (Table 1). After exclusion inclusion criteria considerations, underwent examinations. Various measurements were obtained such as uncorrected visual acuity (UCVA),...
To report the preliminary results of femtosecond laser-assisted cataract surgery in Iranian patients.This prospective case series included 21 eyes patients with cataract. Mean patient age was 66.7 ± 10 years. The underwent femtosecond-laser assisted (VICTUS Femtosecond Laser Platform: Bausch + Lomb) and intraocular lens (IOL) implementation Bina Eye Hospital, Tehran, Iran between May October, 2014. Visual outcomes, pressure (IOP), complications were evaluated three months after surgery.Mean...
BackgroundTo identify pre‐operative factors that influence post‐operative performance of a full‐ring intra‐corneal implant (MyoRing) for the management keratoconus.MethodIn retrospective study, medical records 70 keratoconus eyes consecutive surgical patients with mean age 28.54 ± 6.52-years, who underwent MyoRing implantation using PocketMaker microkeratome (Dioptex GmbH), were included and analysed before visual outcome. Variables assessed age, gender, shape, uncorrected distance acuity,...
Abstract Background Atmospheric Low-Temperature Plasma (ALTP) can be used as an effective tool in conjunctival cyst ablation, but little is known about how ALTP-exposure affects the concentration of inflammatory mediators and also duration responses. Methods We 8 female adult Lewis rats that were followed up 4 groups. The right eye each rat was selected for test, whereas left considered a control. ALTP generated to target 3 spots conjunctiva. digital camera examinations performed follow-up...