Hamd Mohamed

ORCID: 0000-0003-0789-453X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • High voltage insulation and dielectric phenomena
  • Indoor and Outdoor Localization Technologies
  • Underwater Vehicles and Communication Systems
  • Power Line Communications and Noise
  • Bluetooth and Wireless Communication Technologies
  • Advanced Fiber Optic Sensors
  • Network Time Synchronization Technologies
  • Water Systems and Optimization
  • Advanced Wireless Communication Techniques
  • Sensor Technology and Measurement Systems
  • Full-Duplex Wireless Communications
  • Analytical Chemistry and Sensors
  • ECG Monitoring and Analysis
  • Non-Invasive Vital Sign Monitoring
  • Microwave and Dielectric Measurement Techniques
  • Mobile Ad Hoc Networks
  • IoT-based Smart Home Systems
  • Geophysical Methods and Applications
  • PAPR reduction in OFDM
  • Fault Detection and Control Systems
  • RFID technology advancements
  • Cooperative Communication and Network Coding
  • Electrostatic Discharge in Electronics
  • Plasma Diagnostics and Applications
  • Wireless Networks and Protocols

University of Huddersfield
2016-2020

University of Bradford
2019

The term partial discharge (PD) refers to a bridging of insulating material between electrodes that sustain an electric field in high-voltage (HV) systems. Long-term PD activity can lead catastrophic failures HV systems resulting economic, energy and even human life losses. Such losses be avoided by continuously monitoring activity. Existing techniques used for localization including time arrival (TOA) difference (TDOA), are complicated expensive because they require synchronization. In this...

10.3390/s18114000 article EN cc-by Sensors 2018-11-16

Partial discharge (PD) is one of the predominant factors to be controlled ensure reliability and undisrupted functions power generators, motors, Gas Insulated Switchgear (GIS) grid connected distribution equipment, especially in future smart grid. The emergence wireless technology has provided numerous opportunities optimise remote monitoring control facilities that can play a significant role ensuring swift restoration HV plant equipment. In order monitor PD, several approaches have been...

10.1109/ict.2016.7500353 article EN 2016-05-01

Monitoring of partial discharge (PD) activity within high voltage electrical environments is frequently used for the assessment insulation condition. Traditional measurement techniques employ technologies that require either offline installation or power consumption and cost. A wireless sensor network proposed utilizes only received signal strength to locate a high-voltage electricity substation. The comprises low-power low-cost radiometric nodes which receive radiation propagated from...

10.23919/ursigass.2017.8104973 article EN 2017-08-01

Partial Discharge (PD) occurs when insulation containing defects or voids is subject to high voltages. If left untreated PD can degrade until, eventually, catastrophic failure occurs. The detection of current pulses, however, allow incipient faults be identified, located and repaired prior plant failure. Wireless technology has paved the path for monitoring. Software Defined Radio (SDR) a promising technology. Signals from two sources are received at six outdoors locations using an SDR USRP...

10.23919/iconac.2017.8082028 article EN 2017-09-01

Partial discharge (PD) occurs when insulation containing voids is subjected to high voltage (HV). If left untreated, PD can degrade until, eventually, catastrophic failure occurs. The detection of current pulses, however, allow incipient faults be identified, located, and repaired prior plant failure. Traditionally, detected by using galvanic contact methods or capacitive/inductive coupling sensors. This article discusses the use software-defined radio (SDR) for localization presents proof...

10.1109/mie.2019.2942209 article EN IEEE Industrial Electronics Magazine 2019-12-01

Partial discharge (PD) is an electrical that occurs within part of the dielectric separating two HV (High Voltage) conductors. PD causes damage to which typically deteriorates with time. If left untreated, may result in catastrophic insulation failure, destruction equipment, and disruption power supply. The emergence wireless network technology software defined radio has opened new opportunities monitoring early detection failures. This paper proposes use Universal Software Radio Peripheral...

10.1109/icsae.2016.7810220 article EN 2016-10-01

Smart grid is the term used to describe next generation power in which management of electricity distribution enhanced by advanced two-way communications, so that it monitors, protects, and takes decisions automatically optimize operation its interconnected elements. The smart made possible combining communications persistent computing capabilities, enhance control, efficiency, reliability, safety. Using digital technologies, a can transport between suppliers consumers. Such technology...

10.1109/telfor.2017.8249457 article EN 2017-11-01

Partial discharge is a well-established metric for condition monitoring and assessment of high-voltage plant equipment, such as switchgear, transformers transmission lines. Traditional techniques the detection partial pulses involve physical connection sensors to device under observation, requiring separate each item plant, which can be costly time consuming. Wireless measurement provides an attractive alternative, since monitor multiple items simultaneously. However, direct sampling...

10.23919/ursi-at-rasc.2018.8471511 article EN 2018 2nd URSI Atlantic Radio Science Meeting (AT-RASC) 2018-05-01

The term partial discharge (PD) refers to a breakdown in an insulator which bridges two conductors. PD occurs due insulation defects arise as result of high voltage stresses or cracks. Continuous monitoring activity can have significant impact towards mitigating catastrophic failures. In recent times, it has become possible detect and locate on automated basis using wireless sensor technology. this paper, novel technique for detection localization network (WSN) is presented. algorithm based...

10.23919/ursi-at-rasc.2018.8471320 article EN 2018 2nd URSI Atlantic Radio Science Meeting (AT-RASC) 2018-05-01

Partial discharge (PD) refers to the release of energy that occurs due insulation cracks partially bridge conductors. The ultimate consequence PD activity in high voltage systems is a catastrophic failure. continuous monitoring contributes avoidance such failures. In this paper, novel localization algorithm proposed. location was estimated for ten different positions. signal generated by using an emulator, and eight measurement sensors have been used. received converted into distance...

10.23919/iconac.2018.8749101 article EN 2022 27th International Conference on Automation and Computing (ICAC) 2018-09-01

Continuous measurement of partial discharge plays a vital role in monitoring the status high voltage equipment electricity substations. This requires comprehensive supervisory system to detect, monitor, collect and locate activities. Most sensors developed so far require dedicated software hardware platform integrate them into system. A is proposed designed that integrates broadband radiometric robust wireless network. The network easy install reconfigure. Partial activities are collected by...

10.23919/ursi-at-rasc.2018.8471647 article EN 2018 2nd URSI Atlantic Radio Science Meeting (AT-RASC) 2018-05-01

Received signal strength (RSS) based localization of a source is simple but effective technique. In RSS location estimated by converting obtained into distance. this paper, centroid and weighted algorithms has been utilized to locate partial discharge (PD) source. An artificial PD was generated, signals were captured using radio frequency (RF) sensors hence the estimated. The for three different positions. There eight measurement used received converted dBm as input algorithm.

10.1109/wpmc50192.2020.9309452 article EN 2020-10-19

Partial Discharge (PD) is an electrical discharge that occurs within part of the dielectric between two High Voltage (HV) conductors. PD causes damage to which typically deteriorates with time. If left untreated, may result in catastrophic insulation failure, HV equipment destruction, and power supply disruption. detection plays a vital role stations, it can help protect equipment. In this paper comparison systems presented. These are: system based on SDR technology, Radiometric sensors....

10.1109/telfor52709.2021.9653331 article EN 2022 30th Telecommunications Forum (TELFOR) 2021-11-23

In recent years, a significant amount of research has been conducted to explore the benefits network coding in different scenarios, from both theoretical and simulation perspectives. this paper, we utilize queueing theory propose an analytical framework for bidirectional unicast flows multi-hop wireless mesh networks, study throughput inter-flow coding. We analytically determine performance metrics such as probability successful transmission terms collision probability, feedback mechanism...

10.48550/arxiv.1801.02119 preprint EN other-oa arXiv (Cornell University) 2018-01-01

Partial Discharge (PD) detection plays a vital role in electrical power stations, it can help protecting the high voltage equipment, prevent explosion of these equipment and hence preventing catastrophic failure. PD be performed two modes, i.e. frequency domain time domain. The characteristics signal varies due to size type arises from. Wireless emerging technologies such as Software Defined Radio (SDR) used for detection. In this paper source were employed generate signals,...

10.1109/telfor51502.2020.9306600 article EN 2022 30th Telecommunications Forum (TELFOR) 2020-11-24