Shen Zhao

ORCID: 0000-0003-1736-6378
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Particle accelerators and beam dynamics
  • Particle Accelerators and Free-Electron Lasers
  • Superconducting Materials and Applications
  • Advanced MRI Techniques and Applications
  • Magnetic confinement fusion research
  • Medical Imaging Techniques and Applications
  • Sparse and Compressive Sensing Techniques
  • Direction-of-Arrival Estimation Techniques
  • Indoor and Outdoor Localization Technologies
  • Power Systems and Technologies
  • Target Tracking and Data Fusion in Sensor Networks
  • Topology Optimization in Engineering
  • Seismic Imaging and Inversion Techniques
  • Lightning and Electromagnetic Phenomena
  • Advanced X-ray Imaging Techniques
  • High voltage insulation and dielectric phenomena
  • Global Energy and Sustainability Research
  • Composite Structure Analysis and Optimization
  • Atomic and Subatomic Physics Research
  • Atomic and Molecular Physics
  • Muon and positron interactions and applications
  • Wireless Networks and Protocols
  • Advanced Electron Microscopy Techniques and Applications
  • Soil Moisture and Remote Sensing
  • Advanced Battery Technologies Research

Michigan State University
2014-2024

Chinese Academy of Sciences
2024

Jiangxi University of Science and Technology
2024

Stanford University
2022-2023

The Ohio State University
2020-2022

Northwestern Polytechnical University
2019

Nanjing University of Aeronautics and Astronautics
2014

Shanghai Electric (China)
2014

National University of Defense Technology
2013-2014

Ordnance Engineering College
2014

Systemic lupus erythematosus (systemic erythematosus, SLE) may affect the development of chondromalacia patellae (CMP) through immune mechanism; in order to investigate causal effect between SLE and patellae, genome-wide association study (GWAS) was conducted a large European population. GWAS), mutually independent loci associated with respectively were extracted as instrumental variables (SNPs), three Mendelian randomisation (MR) analyses applied relationship, i.e., inverse variance...

10.54097/8pe7xc44 article EN cc-by-nc International Journal of Biology and Life Sciences 2025-01-21

Peer practice teaching is a kind of student-oriented method, which refers to the clinical skills, so that students can learn and independently, teach each other, correct think exchange discuss within team, no longer just directly inculcate content study students, but provide with problematic situations, some cases problems in course, actively think, independently explore, conducting practical activities on their own The application peer education reform skills promotes interns’ independent...

10.56397/crms.2025.03.04 article EN Current Research in Medical Sciences 2025-03-01

It has been promising to provide personalized services for improving our living environment in support of information technologies. Sitting is one the frequent actions daily life, especially people who work office. In this paper, we present design and implementation a sensing cushion. The cushion's about seated postures can be used help avoid adverse effects sitting long periods time or predict activities human-computer interface. seat pan backrest surface mounted with simple binary valued...

10.1109/mfi.2012.6343048 article EN 2012-09-01

A new data acquisition system including a Field Programmable Gate Array (FPGA) based time-resolved scaler was developed for laser-induced fluorescence and beam bunch coincidence measurements. The FPGA tested in collinear laser-spectroscopy experiment on radioactive 37K at the BEam COoler LAser spectroscopy (BECOLA) facility National Superconducting Cyclotron Laboratory Michigan State University. 1.29 μs width from buncher repetition rate of 2.5 Hz led to background suppression factor 3.1 ×...

10.1063/1.4895461 article EN Review of Scientific Instruments 2014-09-01

Imaging the spatial precession cone-shaped targets with narrowband radar is a new technical approach in mid-course recognition problem. However, most existing time-frequency methods still have some inevitable deficiencies for extracting micro-Doppler information practical applications, which leads to blurring of image. A imaging algorithm proposed. The instantaneous frequency each scattering point gained by using improved Hilbert-Huang transform, then positions points parameter domain are...

10.1109/jsee.2014.00112 article EN Journal of Systems Engineering and Electronics 2014-12-01

Purpose To present a computational procedure for accelerated, calibrationless magnetic resonance image (Cl‐MRI) reconstruction that is fast, memory efficient, and scales to high‐dimensional imaging. Theory Methods Cl‐MRI methods can enable high acceleration rates flexible sampling patterns, but their clinical application limited by complexity large footprint. The proposed procedure, HIgh‐dimensional fast convolutional framework (HICU), provides memory‐efficient recovery of unsampled k‐space...

10.1002/mrm.28721 article EN Magnetic Resonance in Medicine 2021-04-04

A novel algorithm for the mobile station (MS) location estimation with none line of sight (NLOS) error in wireless network is proposed this paper. In algorithm, MS problem formulated as a simple linear approximation vector space data corrupted by NLOS errors. The M-estimator employed to eliminate errors, and recursive developed solve M-estimation normal equations. Compared conventional algorithms, does not rely on prior knowledge statistical model measurement noise. Another advantage that...

10.1109/iscas.2008.4541633 article EN 1993 IEEE International Symposium on Circuits and Systems 2008-05-01

The Facility for Rare Isotope Beams driver linac was designed acceleration of multiple-charge-state beams after the stripping at ion beam energies 17 to $20\text{ }\text{ }\mathrm{MeV}\mathrm{/u}$ depending on species. includes a 180\ifmmode^\circ\else\textdegree\fi{} achromatic bend select multiple charge states further and dump unwanted first 45\ifmmode^\circ\else\textdegree\fi{} magnet. Two rf rebunchers between stripper segment 2 (LS2) are required minimize effective emittance growth...

10.1103/physrevaccelbeams.23.042002 article EN cc-by Physical Review Accelerators and Beams 2020-04-08

In phase-contrast magnetic resonance imaging (PC-MRI), spin velocity contributes to the phase measured at each voxel. Therefore, estimating from potentially wrapped measurements is task of solving a system noisy congruence equations. We propose Phase Recovery Multiple Wrapped Measurements (PRoM) as fast, approximate maximum likelihood estimator multi-coil data with possible amplitude attenuation due dephasing. The can recover fullest extent unambiguous velocities, which greatly exceed twice...

10.1109/tmi.2022.3193132 article EN IEEE Transactions on Medical Imaging 2022-07-21

The radio-frequency quadrupole (RFQ) at the Facility for Rare Isotope Beams (FRIB) is a 4-vane type cavity designed to accelerate heavy ion beams with charge states Q/A between 1/7 and 1/3 from 12 keV/u 0.5 MeV/u. RFQ was assembled in FRIB tunnel November 2016. Bead-pull measurements tuning were performed low RF power. has been conditioned 59 kW August 2017, which sufficient Key Performance Parameter (KPP) beams, Argon Krypton. successfully commissioned KPP CW regime October 2017. 40Ar9+...

10.1088/1742-6596/1067/5/052010 article EN Journal of Physics Conference Series 2018-09-01

We report on the first detailed beam test attesting fundamental principle behind development of high-current-efficiency ultrafast electron microscope systems where a radio-frequency cavity is incorporated as condenser lens in delivery system. To allow experiment to be carried out with sufficient resolution probe performance at emittance floor, new cascade loop RF controller system developed reduce noise floor. Temporal 50 femtoseconds full-width-at-half-maximum and detection sensitivity...

10.48550/arxiv.2401.00915 preprint EN cc-by arXiv (Cornell University) 2024-01-01

Download This Paper Open PDF in Browser Add to My Library Share: Permalink Using these links will ensure access this page indefinitely Copy URL DOI

10.2139/ssrn.4773871 preprint EN 2024-01-01

We consider the maximum likelihood (ML) parameter estimation problem for mixed integer linear models with arbitrary noise covariance. This appears in applications such as single frequency estimation, phase contrast imaging, and direction of arrival (DoA) estimation. Parameter estimates are found by solving a closest lattice point problem, which requires basis. In this letter, we present basis construction ML conclude simulated results from DoA imaging.

10.1109/lsp.2023.3324833 article EN IEEE Signal Processing Letters 2023-01-01

10.4156/ijact.vol4.issue19.40 article EN International Journal of Advancements in Computing Technology 2012-10-30

In phase-contrast magnetic resonance imaging (PC-MRI), the velocity of spins at a voxel is encoded in image phase. The strength encoding gradient offers trade-off between velocity-to-noise ratio (VNR) and extent phase aliasing. Phase differences provide invariance to an unknown background Existing literature proposes processing reduced set difference equations, simplifying unwrapping problem expense VNR or unaliased range velocities, both. Here, we demonstrate that fullest unambiguous...

10.1109/isbi52829.2022.9761589 article EN 2022 IEEE 19th International Symposium on Biomedical Imaging (ISBI) 2022-03-28

10.18429/jacow-ipac2018-tupal039 article EN 9th Int. Particle Accelerator Conf. (IPAC'18), Vancouver, BC, Canada, 29 April-04 May 2018 2018-06-01

A platform of spatial estimation, which is based on Matlab GUI, was established. We use to do analysis different parameters (Signal-to-noise ratio, the number snapshots, antenna elements, targets) and simulate results with algorithm. In addition, we a GUI present simulations in interface-friendly way.

10.4028/www.scientific.net/amm.556-562.3357 article EN Applied Mechanics and Materials 2014-05-01
Coming Soon ...