Sukgyu Koh

ORCID: 0000-0003-4764-2089
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Stroke Rehabilitation and Recovery
  • Transcranial Magnetic Stimulation Studies
  • Botulinum Toxin and Related Neurological Disorders
  • Pain Management and Treatment
  • Biodiesel Production and Applications
  • Biofuel production and bioconversion
  • Musculoskeletal pain and rehabilitation
  • Soft Robotics and Applications
  • Clinical Nutrition and Gastroenterology
  • Thermochemical Biomass Conversion Processes
  • Shoulder Injury and Treatment
  • Cerebral Palsy and Movement Disorders
  • Esophageal and GI Pathology

Universiti Tenaga Nasional
2024

Seoul National University
2016-2023

Spasticity is an important factor in designing wearable and lightweight exoskeleton neurorehabilitation robots. The proposed study evaluates biomechanical reactions of robot to spasticity establishes relevant guidelines for design. A two-axis used evaluate a group 20 patients post-stroke with spastic elbow and/or wrist joints. All subjects are given isokinetic movements at various angular velocities within the capable range motion both resistance torque corresponding position each joint...

10.1109/tnsre.2017.2714203 article EN IEEE Transactions on Neural Systems and Rehabilitation Engineering 2017-06-09

Mirror therapy has been performed as effective occupational in a clinical setting for functional recovery of hemiplegic arm after stroke. It is conducted by eliciting an illusion through use mirror if the moving real-time while healthy arm. can facilitate brain neuroplasticity activation sensorimotor cortex. However, conventional critical limitation that not actually moving. Thus, we developed 2-axis robot system simple add-on module using closed feedback mechanism, which enables movement We...

10.3791/54521 article EN Journal of Visualized Experiments 2016-08-15

A novel robotic mirror therapy system was recently developed to provide proprioceptive stimulus the hemiplegic arm during a therapy. Validation of performed confirm its synchronicity prior clinical study. The mean error angle range between intact and robot 1.97 4.59 degrees. 56-year-old male who had right middle cerebral artery infarction 11 months ago received for ten 30-minute sessions 2 weeks. Clinical evaluation functional magnetic resonance imaging (fMRI) studies were before after...

10.3346/jkms.2017.32.10.1568 article EN cc-by-nc Journal of Korean Medical Science 2017-01-01

Abstract In the near future, aviation industry is expected to significantly increase usage of “drop-in” bio-jet fuel as technologies in biofuel production advances and matures. Given high rate growth sector, demand for aerial transportation passenger cargo projected by two-fold next twenty years. This will raise global consumption an estimated 22.48 quadrillion British thermal unit (BTU) 2040. To meet these energy demands, it necessary develop alternative sustainable methods produce jet...

10.1088/1755-1315/1372/1/012036 article EN IOP Conference Series Earth and Environmental Science 2024-07-01

Mirror therapy has been performed as effective occupational in a clinical setting for functional recovery of hemiplegic arm after stroke. It is conducted by eliciting an illusion through use mirror if the moving real-time while healthy arm. can facilitate brain neuroplasticity activation sensorimotor cortex. However, conventional critical limitation that not actually moving. Thus, we developed 2-axis robot system simple add-on module using closed feedback mechanism, which enables movement We...

10.3791/54521-v article EN Journal of Visualized Experiments 2016-08-15

Background: The flexible endoscopy system is a key device for observing the gastrointestinal tract non-invasively in real-time.Traditional endoscopes pose challenges such as musculoskeletal risks due to their heavy weight, and steep learning curve doctors complexity.While robotic have emerged, high-performance gastroenterology department remains undeveloped.This study explores feasibility of developing highperformance gastroscope enhance stability accuracy endoscopic procedures.Materials...

10.61940/jimt.230002 article EN cc-by-nc Journal of Innovative Medical Technology 2023-11-30
Coming Soon ...