Eylem Kekeç

ORCID: 0009-0007-7477-4665
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Radiation Dose and Imaging
  • Radioactivity and Radon Measurements
  • Radiation Shielding Materials Analysis
  • Advanced X-ray and CT Imaging
  • Effects of Radiation Exposure

This study examines the radiation dose levels to which kidney is exposed during stone fragmentation procedures that utilize scopy imaging. The assessment was conducted using Alderson Rando phantom and Thermoluminescent Dosimeter (TLD). examined various exposure parameters measured over time. results suggest a direct correlation between duration dose, emphasizing need monitor fluoroscopic interventions, especially due kidneys' sensitivity radiation. Future research should concentrate on...

10.22399/ijcesen.298 article EN International Journal of Computational and Experimental Science and Engineering 2024-03-04

Objectives: This study aims to investigate the effect of full- and half-rotation angles on patient radiation dose quantitative image quality in CBCT imaging head neck region. Methods: A total 67 TLDs were used for dosimetry 16 different regions slices anthropometric phantom. The Hyperion X9 Pro (MyRay, Cefla, Imola, Italy) device was with a 90 kV pulsed beam 13x16e FOV size. Two separate modes (Regular 360 0 Quick 180 0) tested, mA determined by software. Effective doses (EDs) calculated...

10.2174/0115734056316438241203095215 article EN Current Medical Imaging Formerly Current Medical Imaging Reviews 2025-04-17

Abstract: This study aims to evaluate the radiation dose impacting thyroid tissue during C-arm fluoroscopy using Alderson Rando phantom and thermoluminescent dosimeters (TLD-100). Given sensitivity of thyroid, understanding is crucial for patient safety. The phantom, representing a human equivalent, was employed exposure assessment. TLD-100 were strategically placed in region phantom's 9th section. Measurements taken at 0.5, 1, 2, 4, 8-minute intervals. conducted Istanbul...

10.22399/ijasrar.13 article EN 2024-02-26

This study systematically explores the temporal variations in radiation dose incurred by reproductive organs during simulated scopy procedures. Focusing on a scenario of repairing fictitious right hip fracture, investigation utilizes Alderson Rando phantom and Thermoluminescent Dosimeters (TLDs) to meticulously examine dynamics exposure. The employs TLD-100 dosimeters placed specific regions phantom, mimicking left ovaries uteri. simulation is conducted replicate procedure, with X-ray tube's...

10.1016/j.jrras.2024.100896 article EN cc-by-nc-nd Journal of Radiation Research and Applied Sciences 2024-04-10
Coming Soon ...