A Numerical Study of Ash Deposition Characteristics in a 660MW Supercritical Tangential Boiler
Pulverized coal-fired boiler
Deposition
DOI:
10.1002/adts.202300133
Publication Date:
2023-09-01T06:12:40Z
AUTHORS (8)
ABSTRACT
Abstract When the boiler is operated at different loads, characteristics of ash deposition in will change accordingly. In this paper, a 660MW tangentially fired power taken as research object. The combustion and on walls are studied by numerical simulation. results show that: 1) middle lower part furnace wall, more particles deposited, temperature higher CO concentration higher, so slagging easy to occur. 2) accumulation bottom hopper mainly comes from two layers burners for >98%. 3) ratio negatively correlated with height burner. 4) With particle diameter increasing, burner increases significantly. Selecting pulverized coal size 65 µm can reduce risk deposition.