Measurement and analysis of neutron and gamma-ray emission rates, other fusion products, and power in electrochemical cells having Pd cathodes
0301 basic medicine
03 medical and health sciences
7. Clean energy
DOI:
10.1007/bf02627578
Publication Date:
2007-05-08T05:33:54Z
AUTHORS (16)
ABSTRACT
Results of experiments intended to reproduce cold fusion phenomena originally reported by Fleischmann, Pons, and Hawkins are presented. These experiments were performed on a pair of matched electrochemical cells containing 0.1×9 cm Pd rods that were operated for 10 days. The cells were analyzed by the following means: (1) constant temperature calorimetry, (2) neutron counting and γ-ray spectroscopy, (3) mass spectral analysis of4He in effluent gases, and4He and3He within the Pd metal, (4) tritium analysis of the electrolyte solution, and (5) x-ray photoelectron spectroscopy of the Pd cathode surface. Within estimated levels of accuracy, no excess power output or any other evidence of fusion products was detected.