Benefits of minocycline and rifampin-impregnated central venous catheters
Colonization
Risk
Catheterization, Central Venous
Critical Illness
Blood-Stream Infection
Minocycline
Critically-Ill Patients
03 medical and health sciences
Catheters, Indwelling
Drug Delivery Systems
0302 clinical medicine
Double-Blind Method
Intensive-Care-Unit
3201 Ciencias clínicas
Blood-Borne Pathogens
Humans
Prospective Studies
Cross Infection
Prevention
Chlorhexidine
Bacterial Infections
Anti-Bacterial Agents
3. Good health
Intensive Care Units
Treatment Outcome
Adherence
Rifampin
32 Ciencias médicas
DOI:
10.1007/s00134-004-2378-2
Publication Date:
2004-07-19T01:48:56Z
AUTHORS (10)
ABSTRACT
To determine the efficacy of minocycline and rifampin-impregnated catheters compared to non-impregnated catheters in critically ill patients.Prospective, randomized, double-blind, controlled, multicenter trial.Intensive care units of seven acute-care teaching hospitals in Spain. PATIENTS. Intensive care unit patients requiring triple-lumen central venous catheter for more than 3 days.At catheter insertion, 228 patients were randomized to minocycline and rifampin-impregnated catheters and 237 to non-impregnated catheters. Skin, catheter tip, subcutaneous segment, hub cultures, peripheral blood and infusate cultures were performed at catheter withdrawal. The rate of colonization, catheter-related bloodstream infection (CRBSI) and catheter-related clinical infectious complications (purulence at the insertion site or CRBSI) were assessed.In the intention-to-treat analysis (primary analysis), the episodes per 1000 catheter days of clinical infectious complications decreased from 8.6 to 5.7 (RR =0.67, 95% CI 0.31-1.44), CRBSI from 5.9 to 3.1 (RR =0.53, 95% CI 0.2-1.44) and tip colonization from 24 to 10.4 (RR =0.43, 95% CI 0.26-0.73). Antimicrobial-impregnated catheters were associated with a significant decrease of coagulase-negative staphylococci colonization (RR =0.24, 95% CI 0.13-0.45) and a significant increase of Candida spp. colonization (RR =5.84, 95% CI 1.31-26.1).The use of antimicrobial-impregnated catheters was associated with a significantly lower rate of coagulase-negative staphylococci colonization and a significant increase in Candida spp. colonization, although a decrease in CRBSI, increase in 30-day survival or reduced length of stay was not observed.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (35)
CITATIONS (84)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....