Computed tomography myocardial perfusion vs 15O-water positron emission tomography and fractional flow reserve

Male Adenosine Computed Tomography Angiography Vasodilator Agents Coronary Artery Disease Coronary Angiography Sensitivity and Specificity 03 medical and health sciences 0302 clinical medicine Oxygen Radioisotopes Predictive Value of Tests Humans Prospective Studies Aged Coronary Stenosis Myocardial Perfusion Imaging Middle Aged 3. Good health Fractional Flow Reserve, Myocardial Radiology Nuclear Medicine and imaging Positron-Emission Tomography Exercise Test Female Tomography, X-Ray Computed Cardiac
DOI: 10.1007/s00330-016-4404-5 Publication Date: 2016-06-23T00:19:43Z
ABSTRACT
Computed tomography (CT) can perform comprehensive cardiac imaging. We compared CT coronary angiography (CTCA) and CT myocardial perfusion (CTP) with 15O-water positron emission tomography (PET) and invasive coronary angiography (ICA) with fractional flow reserve (FFR).51 patients (63 (61-65) years, 80 % male) with known/suspected coronary artery disease (CAD) underwent 320-multidetector CTCA followed by "snapshot" adenosine stress CTP. Of these 22 underwent PET and 47 ICA/FFR. Obstructive CAD was defined as CTCA stenosis >50 % and CTP hypoperfusion, ICA stenosis >70 % or FFR <0.80.PET hyperaemic myocardial blood flow (MBF) was lower in obstructive than non-obstructive territories defined by ICA/FFR (1.76 (1.32-2.20) vs 3.11 (2.44-3.79) mL/(g/min), P < 0.001) and CTCA/CTP (1.76 (1.32-2.20) vs 3.12 (2.44-3.79) mL/(g/min), P < 0.001). Baseline and hyperaemic CT attenuation density was lower in obstructive than non-obstructive territories (73 (71-76) vs 86 (84-88) HU, P < 0.001 and 101 (96-106) vs 111 (107-114) HU, P 0.001). PET hyperaemic MBF corrected for rate pressure product correlated with CT attenuation density (r = 0.579, P < 0.001). There was excellent per-patient sensitivity (96 %), specificity (85 %), negative predictive value (90 %) and positive predictive value (94 %) for CTCA/CTP vs ICA/FFR.CT myocardial attenuation density correlates with 15O-water PET MBF. CTCA and CTP can accurately identify obstructive CAD.•CT myocardial perfusion can aid the assessment of suspected coronary artery disease. • CT attenuation density from "snapshot" imaging is a marker of myocardial perfusion. • CT myocardial attenuation density correlates with 15 O-water PET myocardial blood flow. • CT attenuation density is lower in obstructive territories defined by invasive angiography. • Diagnostic accuracy of CTCA+CTP is comparable to invasive angiography + fractional flow reserve.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (41)
CITATIONS (26)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....