Receiver design for the REACH global 21-cm signal experiment

SIGNAL (programming language)
DOI: 10.1007/s10686-024-09975-3 Publication Date: 2025-01-17T04:18:39Z
ABSTRACT
We detail the REACH radiometric system designed to enable measurements of 21-cm neutral hydrogen line. Included is radiometer architecture and end-to-end simulations as well a discussion challenges intrinsic highly-calibratable development. Following this, we share laboratory results based on calculation noise wave parameters utilising an over-constrained least squares approach. For five hours integration custom-made source with comparable impedance that antenna used in field, demonstrate calibration RMSE 80 mK. This paper therefore documents state calibrator data analysis December 2022 Cambridge before shipping South Africa.