Computer assisted determination of acetabular cup orientation using 2D–3D image registration
Adult
Arthroplasty, Replacement, Hip
Acetabulum
03 medical and health sciences
Imaging, Three-Dimensional
0302 clinical medicine
Surgery, Computer-Assisted
Humans
Radiographic Image Interpretation, Computer-Assisted
Computer Simulation
Hip Joint
Tomography, X-Ray Computed
DOI:
10.1007/s11548-010-0407-x
Publication Date:
2010-02-23T18:11:49Z
AUTHORS (2)
ABSTRACT
2D-3D image-based registration methods have been developed to measure acetabular cup orientation after total hip arthroplasty (THA). These methods require registration of both the prosthesis and the CT images to 2D radiographs and compute implant position with respect to a reference. The application of these methods is limited in clinical practice due to two limitations: (1) the requirement of a computer-aided design (CAD) model of the prosthesis, which may be unavailable due to the proprietary concerns of the manufacturer, and (2) the requirement of either multiple radiographs or radiograph-specific calibration, usually unavailable for retrospective studies. In this paper, we propose a new method to address these limitations.A new formulation for determination of post-operative cup orientation, which couples a radiographic measurement with 2D-3D image matching, was developed. In our formulation, the radiographic measurement can be obtained with known methods so that the challenge lies in the 2D-3D image matching. To solve this problem, a hybrid 2D-3D registration scheme combining a landmark-to-ray 2D-3D alignment with a robust intensity-based 2D-3D registration was used. The hybrid 2D-3D registration scheme allows computing both the post-operative cup orientation with respect to an anatomical reference and the pelvic tilt and rotation with respect to the X-ray imaging table/plate. The method was validated using 2D adult cadaver hips.Using the hybrid 2D-3D registration scheme, our method showed a mean accuracy of 1.0 +/- 0.7 degrees (range from 0.1 degrees to 2.0 degrees) for inclination and 1.7 +/- 1.2 degrees (range from 0.0 degrees to 3.9 degrees) for anteversion, taking the measurements from post-operative CT images as ground truths.Our new solution formulation and the hybrid 2D-3D registration scheme facilitate estimation of post-operative cup orientation and measurement of pelvic tilt and rotation.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (44)
CITATIONS (9)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....