Injection transient study using a two-frequency bunch length measurement system at the SSRF
Transient (computer programming)
Length measurement
Oscillation (cell signaling)
SIGNAL (programming language)
DOI:
10.1007/s41365-017-0247-2
Publication Date:
2017-05-26T03:39:57Z
AUTHORS (4)
ABSTRACT
The bunch length can be measured by comparison of two frequency components of a synchrotron beam signal. An online bunch length measurement system has been implemented based on this method. Working frequencies of 3 GHz and 500 MHz were selected, and the raw data was acquired by digital oscilloscope and was resampled and analyzed using the MATLAB software platform at bunch-by-bunch rate. The constructed system was employed to study the bunch length synchronous oscillation phenomenon during injection. The beam experiments demonstrated a time resolution of less than 0.5 ps.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (20)
CITATIONS (11)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....