Automatic fetal biometry prediction using a novel deep convolutional network architecture
Biometry
Image classification
SEGMENTATION
Deep learning
Convolutional neural network
info:eu-repo/classification/ddc/616.8
ddc:616.0757
CLASSIFICATION
ddc:616.8
Fetal biometry
info:eu-repo/classification/ddc/616.0757
03 medical and health sciences
0302 clinical medicine
Image Processing, Computer-Assisted
Humans
Neural Networks, Computer
Ultrasound imaging
Head
Algorithms
Ultrasonography
DOI:
10.1016/j.ejmp.2021.06.020
Publication Date:
2021-07-06T16:16:41Z
AUTHORS (10)
ABSTRACT
Fetal biometric measurements face a number of challenges, including the presence of speckle, limited soft-tissue contrast and difficulties in the presence of low amniotic fluid. This work proposes a convolutional neural network for automatic segmentation and measurement of fetal biometric parameters, including biparietal diameter (BPD), head circumference (HC), abdominal circumference (AC), and femur length (FL) from ultrasound images that relies on the attention gates incorporated into the multi-feature pyramid Unet (MFP-Unet) network.The proposed approach, referred to as Attention MFP-Unet, learns to extract/detect salient regions automatically to be treated as the object of interest via the attention gates. After determining the type of anatomical structure in the image using a convolutional neural network, Niblack's thresholding technique was applied as pre-processing algorithm for head and abdomen identification, whereas a novel algorithm was used for femur extraction. A publicly-available dataset (HC18 grand-challenge) and clinical data of 1334 subjects were utilized for training and evaluation of the Attention MFP-Unet algorithm.Dice similarity coefficient (DSC), hausdorff distance (HD), percentage of good contours, the conformity coefficient, and average perpendicular distance (APD) were employed for quantitative evaluation of fetal anatomy segmentation. In addition, correlation analysis, good contours, and conformity were employed to evaluate the accuracy of the biometry predictions. Attention MFP-Unet achieved 0.98, 1.14 mm, 100%, 0.95, and 0.2 mm for DSC, HD, good contours, conformity, and APD, respectively.Quantitative evaluation demonstrated the superior performance of the Attention MFP-Unet compared to state-of-the-art approaches commonly employed for automatic measurement of fetal biometric parameters.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (47)
CITATIONS (47)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....