Prediction of bone strength by μCT and MDCT-based finite-element-models: How much spatial resolution is needed?
Male
Compressive Strength
data analysis
Finite Element Analysis
0206 medical engineering
02 engineering and technology
Models, Biological
Sensitivity and Specificity
Thoracic Vertebrae
Absorptiometry, Photon
Bone Density
Elastic Modulus
Tensile Strength
Multidetector Computed Tomography
Humans
Computer Simulation
Aged
Aged, 80 and over
FEM
Reproducibility of Results
Bone structure
Radiographic Image Enhancement
Radiographic Image Interpretation, Computer-Assisted
Female
Stress, Mechanical
DOI:
10.1016/j.ejrad.2013.10.024
Publication Date:
2013-11-08T03:45:21Z
AUTHORS (9)
ABSTRACT
Finite-element-models (FEM) are a promising technology to predict bone strength and fracture risk. Usually, the highest spatial resolution technically available is used, but this requires excessive computation time and memory in numerical simulations of large volumes. Thus, FEM were compared at decreasing resolutions with respect to local strain distribution and prediction of failure load to (1) validate MDCT-based FEM and to (2) optimize spatial resolution to save computation time.20 cylindrical trabecular bone specimens (diameter 12 mm, length 15-20mm) were harvested from elderly formalin-fixed human thoracic spines. All specimens were examined by micro-CT (isotropic resolution 30 μm) and whole-body multi-row-detector computed tomography (MDCT, 250 μm × 250 μm × 500 μm). The resolution of all datasets was lowered in eight steps to ~ 2,000 μm × 2000 μm × 500 μm and FEM were calculated at all resolutions. Failure load was determined by biomechanical testing. Probability density functions of local micro-strains were compared in all datasets and correlations between FEM-based and biomechanically measured failure loads were determined.The distribution of local micro-strains was similar for micro-CT and MDCT at comparable resolutions and showed a shift toward higher average values with decreasing resolution, corresponding to the increasing apparent trabecular thickness. Small micro-strains (εeff<0.005) could be calculated down to 250 μm × 250 μm × 500 μm. Biomechanically determined failure load showed significant correlations with all FEM, up to r=0.85 and did not significantly change with lower resolution but decreased with high thresholds, due to loss of trabecular connectivity.When choosing connectivity-preserving thresholds, both micro-CT- and MDCT-based finite-element-models well predicted failure load and still accurately revealed the distribution of local micro-strains in spatial resolutions, available in vivo (250 μm × 250 μm × 500 μm), that thus seemed to be the optimal compromise between high accuracy and low computation time.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (37)
CITATIONS (31)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....