Manual In-line Stabilization Increases Pressures Applied by the Laryngoscope Blade during Direct Laryngoscopy and Orotracheal Intubation
Adult
Male
Laryngoscopy
Laryngoscopes
Middle Aged
3. Good health
03 medical and health sciences
0302 clinical medicine
Intubation, Intratracheal
Pressure
Transducers, Pressure
Humans
Female
Follow-Up Studies
DOI:
10.1097/aln.0b013e318190b556
Publication Date:
2008-12-17T08:30:17Z
AUTHORS (7)
ABSTRACT
Background
Manual in-line stabilization (MILS) is recommended during direct laryngoscopy and intubation in patients with known or suspected cervical spine instability. Because MILS impairs glottic visualization, the authors hypothesized that anesthesiologists would apply greater pressure during intubations with MILS than without.
Methods
Nine anesthetized and pharmacologically paralyzed patients underwent two sequential laryngoscopies and intubations, one with MILS and one without, in random order. A transducer array along a Macintosh 3 laryngoscope blade continuously measured applied pressures, and glottic view was characterized.
Results
With MILS, glottic visualization was worse in six patients, and intubation failure occurred in two of these six patients. Maximum laryngoscope pressure at best glottic view was greater with MILS than without (717 +/- 339 mmHg vs. 363 +/- 121 mmHg, respectively; n = 8; P = 0.023). Other measures of pressure application also indicated comparable increases with MILS.
Conclusion
Pressures applied to airway tissues by the laryngoscope blade are secondarily transmitted to the cervical spine and result in cranio-cervical motion. In the presence of cervical instability, impaired glottic visualization and secondary increases in pressure application with MILS have the potential to increase pathologic cranio-cervical motion.