A 50 Gb/s NRZ Modulated 850 nm VCSEL Transmitter Operating Error Free to 90 °C
0211 other engineering and technologies
02 engineering and technology
DOI:
10.1109/jlt.2014.2363848
Publication Date:
2014-10-20T14:35:51Z
AUTHORS (8)
ABSTRACT
We report on the properties of an 850nm VCSEL transmitter running at 50Gb/s with NRZ modulation from 30°C to 90°C. This is the highest transmitter operating temperature at 50Gb/s for a VCSEL link of any wavelength. This achievement is made possible by a combination of a high speed VCSEL design and driver and receiver circuits that incorporate equalization. Without equalization, the highest temperature attained with BER <1E-12 is 57°C.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (36)
CITATIONS (73)
EXTERNAL LINKS
PlumX Metrics