Patch test results with the European baseline series, 2019/20—Joint European results of the ESSCA and the EBS working groups of the ESCD, and the GEIDAC
Patch test
Patch Testing
Contact Allergy
DOI:
10.1111/cod.14170
Publication Date:
2022-06-09T10:49:46Z
AUTHORS (25)
ABSTRACT
Continual analyses of patch test results with the European baseline series (EBS) serve both contact allergy surveillance and auditing value included allergens.To present current EBS testing, obtained in 53 departments 13 countries during 2019 2020.Anonymised or pseudonymised individual data partly aggregated on demographic/clinical characteristics rest were prospectively collected centrally pooled analysed.In 2020, 22 581 patients tested EBS. Sensitization to nickel remained most common (19.8 [19.2-20.4]% positivity [95% confidence interval]). Fragrance mix I Myroxylon pereirae yielded very similar 6.80 (6.43-7.19)% 6.62 (6.25-7.00)% positivity, respectively. Formaldehyde at 2% aq. almost one percentage point more positive reactions than 1% concentration (2.49 [2.16-2.85]% vs. 1.59 [1.33-1.88]); methylchloroisothiazolinone/methylisothiazolinone (MCI/MI) MI alone up around 5% positives. Among new additions, propolis was commonly (3.48 [3.16-3.82]%), followed by 2-hydroxyethyl methacrylate (2.32 [2.0-2.68]%).Ongoing prevalence sensitization contributes an up-to-date containing frequent and/or relevant sensitizers for routine testing Europe.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (63)
CITATIONS (58)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....