Accuracy of photogrammetry, intraoral scanning, and conventional impression techniques for complete-arch implant rehabilitation: an in vitro comparative study
Dental Implants
Dental Impression Technique
Research
Dental implants
RK1-715
Models, Dental
Edentulous
03 medical and health sciences
Imaging, Three-Dimensional
0302 clinical medicine
Intraoral scanning
Conventional impression
Dentistry
Photogrammetry
Computer-Aided Design
Humans
Dental impression technique
DOI:
10.1186/s12903-021-02005-0
Publication Date:
2021-12-10T20:02:45Z
AUTHORS (5)
ABSTRACT
Abstract
Background
To compare the accuracy of photogrammetry, intraoral scanning and conventional impression techniques for complete-arch implant rehabilitation.
Methods
A master cast containing 6 implant abutment replicas was fabricated. Group PG: digital impressions were taken 10 times using a photogrammetry system; Group IOS: intraoral scanning was performed to fabricate 10 digital impressions; Group CNV: splinted open-tray impression technique was used to fabricate 10 definitive casts. The master cast and conventional definitive casts were digitized with a laboratory reference scanner. For all STL files obtained, scan bodies were converted to implant abutment replicas using a digital library. The accuracy of a digitizer was defined by 2 main parameters, trueness and precision. "Trueness" was used to describe the deviation between test files and reference file, and "precision" was used to describe the closeness between test files. Then, the trueness and precision of three impression techniques were evaluated and statistically compared (α = 0.05).
Results
The median trueness was 24.45, 43.45 and 28.70 μm for group PG, IOS and CNV; Group PG gave more accurate trueness than group IOS (P < 0.001) and group CNV (P = 0.033), group CNV showed more accurate trueness than group IOS (P = 0.033). The median precision was 2.00, 36.00 and 29.40 μm for group PG, IOS and CNV; Group PG gave more accurate precision than group IOS (P < 0.001) and group CNV (P < 0.001), group CNV showed more accurate precision than IOS (P = 0.002).
Conclusions
For complete-arch implant rehabilitation, the photogrammetry system showed the best accuracy of all the impression techniques evaluated, followed by the conventional impression technique, and the intraoral scanner provided the least accuracy.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (43)
CITATIONS (51)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....