EVAPORATION HEAT TRANSFER PERFORMANCE OF NOZZLE-SPRAYED AMMONIA ON A HORIZONTAL TUBE
Saturation (graph theory)
Spray characteristics
Boiling point
DOI:
10.1615/ichmt.2000.thersieprocvol2thersieprocvol1.420
Publication Date:
2011-03-28T17:45:31Z
AUTHORS (3)
ABSTRACT
Spray evaporation experiment was conducted using commercial nozzles distributing liquid ammonia on a horizontal plain stainless-steel tube of 1.9 cm diameter. The average local spray flow rate measured, and varied from 0.0138 to 0.0777 kg/(s-m). saturation temperature tested −23.3 10 °C, heat flux 8 60 kW/m2. effects flux, temperature, rate, nozzle height were investigated. Both standard-angle wide-angle tested. results are compared with pool boiling data obtained in the present published results.