Suspected transmission of tuberculosis in a maternity ward from a smear-positive nurse: preliminary results of clinical evaluations and testing of neonates potentially exposed, Rome, Italy, 1 January to 28 July 2011

Gold standard (test) Active tuberculosis
DOI: 10.2807/ese.16.40.19984-en Publication Date: 2017-10-04T10:08:58Z
ABSTRACT
We report preventive measures adopted after tuberculosis (TB) transmission from a nurse to newborn assessed in late July 2011. All exposed neonates born between January and 2011 were clinically evaluated tested by QuantiFERON TB gold in-tube; newborns testing positive referred for prophylaxis. Of 1,340 newborns, 118 (9%) no other active cases of found. Active surveillance will be continued over the next three years all those exposed.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (0)
CITATIONS (16)