Inter- and Intra-Observer Variability and the Effect of Experience in Cine-MRI for Adhesion Detection
tissue adhesions
Computer applications to medicine. Medical informatics
Radboudumc 10: Reconstructive and regenerative medicine Surgery
R858-859.7
Radboud University Medical Center
QA75.5-76.95
Radboudumc 15: Urological cancers Medical Imaging
CHRONIC ABDOMINAL-PAIN
observer variation
Article
03 medical and health sciences
0302 clinical medicine
Electronic computers. Computer science
Photography
(MeSH)
magnetic resonance imaging
Radboudumc 14: Tumours of the digestive tract Surgery
INTRAABDOMINAL ADHESIONS
TR1-1050
DOI:
10.3390/jimaging9030055
Publication Date:
2023-02-23T08:25:56Z
AUTHORS (23)
ABSTRACT
Cine-MRI for adhesion detection is a promising novel modality that can help the large group of patients developing pain after abdominal surgery. Few studies into its diagnostic accuracy are available, and none address observer variability. This retrospective study explores the inter- and intra-observer variability, diagnostic accuracy, and the effect of experience. A total of 15 observers with a variety of experience reviewed 61 sagittal cine-MRI slices, placing box annotations with a confidence score at locations suspect for adhesions. Five observers reviewed the slices again one year later. Inter- and intra-observer variability are quantified using Fleiss’ (inter) and Cohen’s (intra) κ and percentage agreement. Diagnostic accuracy is quantified with receiver operating characteristic (ROC) analysis based on a consensus standard. Inter-observer Fleiss’ κ values range from 0.04 to 0.34, showing poor to fair agreement. High general and cine-MRI experience led to significantly (p < 0.001) better agreement among observers. The intra-observer results show Cohen’s κ values between 0.37 and 0.53 for all observers, except one with a low κ of −0.11. Group AUC scores lie between 0.66 and 0.72, with individual observers reaching 0.78. This study confirms that cine-MRI can diagnose adhesions, with respect to a radiologist consensus panel and shows that experience improves reading cine-MRI. Observers without specific experience adapt to this modality quickly after a short online tutorial. Observer agreement is fair at best and area under the receiver operating characteristic curve (AUC) scores leave room for improvement. Consistently interpreting this novel modality needs further research, for instance, by developing reporting guidelines or artificial intelligence-based methods.
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES (18)
CITATIONS (4)
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....