Study on a steel chimney outer wall with three spiral guide plates in this paper. Research the structure stability and static force analysis under wind loads by using ANSYS Workbench CFX fluid mechanics modular. To prove is more safe stable than old chimney. Provides new transformation basis of as ratio height to diameter large low flexural strength.