performance of a large area gem detector prototype for the upgrade of the cms muon endcap system
Physics - Instrumentation and Detectors
FOS: Physical sciences
Instrumentation and Detectors (physics.ins-det)
01 natural sciences
7. Clean energy
Nuclear and High Energy Physics; Radiology; Nuclear Medicine and Imaging
03 medical and health sciences
0302 clinical medicine
0103 physical sciences
nuclear and high energy physics; radiology, nuclear medicine and imaging; instrumentation
DOI:
10.48550/arxiv.1412.0228
Publication Date:
2014-11-01
AUTHORS (138)
ABSTRACT
Gas Electron Multiplier (GEM) technology is being considered for the forward muon upgrade of the CMS experiment in Phase 2 of the CERN LHC. Its first implementation is planned for the GE1/1 system in the $1.5 < \mid��\mid < 2.2$ region of the muon endcap mainly to control muon level-1 trigger rates after the second long LHC shutdown. A GE1/1 triple-GEM detector is read out by 3,072 radial strips with 455 $��$rad pitch arranged in eight $��$-sectors. We assembled a full-size GE1/1 prototype of 1m length at Florida Tech and tested it in 20-120 GeV hadron beams at Fermilab using Ar/CO$_{2}$ 70:30 and the RD51 scalable readout system. Four small GEM detectors with 2-D readout and an average measured azimuthal resolution of 36 $��$rad provided precise reference tracks. Construction of this largest GEM detector built to-date is described. Strip cluster parameters, detection efficiency, and spatial resolution are studied with position and high voltage scans. The plateau detection efficiency is [97.1 $\pm$ 0.2 (stat)]\%. The azimuthal resolution is found to be [123.5 $\pm$ 1.6 (stat)] $��$rad when operating in the center of the efficiency plateau and using full pulse height information. The resolution can be slightly improved by $\sim$ 10 $��$rad when correcting for the bias due to discrete readout strips. The CMS upgrade design calls for readout electronics with binary hit output. When strip clusters are formed correspondingly without charge-weighting and with fixed hit thresholds, a position resolution of [136.8 $\pm$ 2.5 stat] $��$rad is measured, consistent with the expected resolution of strip-pitch/$\sqrt{12}$ = 131.3 $��$rad. Other $��$-sectors of the detector show similar response and performance.<br/>8 pages, 32 figures, submitted to Proc. 2014 IEEE Nucl. Sci. Symposium, Seattle, WA, reference added<br/>
SUPPLEMENTAL MATERIAL
Coming soon ....
REFERENCES ()
CITATIONS ()
EXTERNAL LINKS
PlumX Metrics
RECOMMENDATIONS
FAIR ASSESSMENT
Coming soon ....
JUPYTER LAB
Coming soon ....