- Microgrid Control and Optimization
- Optimal Power Flow Distribution
- HVDC Systems and Fault Protection
- Smart Grid Energy Management
- Integrated Energy Systems Optimization
- Electric Vehicles and Infrastructure
- Power System Reliability and Maintenance
- Electric Power System Optimization
- Advanced Battery Technologies Research
- Power Systems and Renewable Energy
- High-Voltage Power Transmission Systems
- Smart Grid and Power Systems
- Power Transformer Diagnostics and Insulation
- Power Systems and Technologies
- Real-time simulation and control systems
- High voltage insulation and dielectric phenomena
- Thermal Analysis in Power Transmission
- Ferroelectric and Negative Capacitance Devices
- Industrial Technology and Control Systems
- Lightning and Electromagnetic Phenomena
- Advanced DC-DC Converters
- Electrical Fault Detection and Protection
- Power System Optimization and Stability
- Advanced Memory and Neural Computing
- Electric Motor Design and Analysis
China Agricultural University
2016-2025
Xinjiang New Energy Research Institute (China)
2021-2025
Hefei University of Technology
2025
Tsinghua University
2011-2024
Inner Mongolia Electric Power (China)
2020-2024
State Grid Corporation of China (China)
2021-2024
Thermal Power Research Institute
2023
University of Shanghai for Science and Technology
2023
Technical University of Denmark
2023
Dalian Jiaotong University
2022
This paper introduces a dc transmission grid with fault-tolerant inductor-capacitor-inductor (LCL) voltage-source converters (VSCs) and using slow protection system based on mechanical circuit breakers (CBs). LCL VSC inherently regulates fault current to levels that can sustain for prolonged periods which avoids insulated-gate bipolar transistor tripping brings significant advantage security reliability aspects. Simple CBs are used at busbars connecting points of each cable, in the same...
Transfer capacities of urban distribution networks need to be increased fulfill the increasing load demands and accommodate distributed generation (DG). However, there are limited spaces build new substations lines, curtailment DGs may happen due voltage violation during DG outputs fluctuation. This paper proposes analyzes various methods convert some existing ac MV lines dc in order form a hybrid ac/dc network, based on which transfer can increased, flexible power shift achieved through...
In recent years, the frequent occurrence of extreme natural disasters has caused huge economic losses, which makes it extremely important to improve resilience distribution networks. With increasing penetration DC sources and loads, urban network is transitioning from AC hybrid AC/DC configuration that can operate in a ring structure. The features flexible interconnections low losses lines break bottleneck traditional restoration methods for networks under disasters, thereby further...
The flexible AC/DC interconnection of low-voltage distribution networks (LVDNs) using soft open points (SOPs) enhances load-carrying capacity and distributed generation (DG) accommodation capability through optimal power shifting considering the complementarity between LVDNs. However, degree interconnected LVDNs is usually affected by periodic change load power, current fixed scheme plays a significant role only during some periods, resulting in low utilization rate equipment. To tackle this...
The large-scale integration of renewable energy sources and new loads, such as distributed photovoltaics electric vehicles, has resulted in frequent power quality issues within distribution networks. Traditional AC networks lack the necessary flexibility have limited capacity to accommodate these loads. Transforming conventional network into an AC-DC hybrid using flexible interconnection devices like Voltage Source Converters can enhance network’s flexibility, mitigating challenges arising...
The fault current in MMC HVDC systems suffers from a quick rising rate and no zero-cross problems, which makes it hard to cut off has become the main problem when promoting dc systems. Among different types of faults, pole-to-pole is most serious one. Hence, clarify discharging mechanism during faults determine influential factors, this paper proposes simplified modeling method for impact factors analysis. proposed uses circuit happen, frequency domain model then established Considering that...
Water environment evaluation is the basis of water resource planning and sustainable utilization. As a successful case coordinated progress ecological protection economic development, Xin’an River Basin model for exploring green development model. However, there are still some problems in synergistic cooperation between two provinces. Exploring differences within basin key entry point solving dilemma governance Basin, optimizing allocation resources, improving overall effectiveness...
Abstract Cyclic adenosine monophosphate (cAMP) plays an important role in many biological processes as a second messenger and cAMP treatment has been reported to extend the lifespan of wild-type Drosophila melanogaster . Our study showed that exogenous improved ageing-related phenotypes by increasing protein level Sirtuins, which prevented metabolic disorders mimic effect calorie restriction. Experiments vitro directly bound SIRT1 SIRT3 consequently increased their activity. These findings...
To mitigate the voltage violation and overloading caused by integration of Distributed Generation (DG) Electric Vehicle Charging (EVC) loads, a feasible solution is to convert some AC medium distribution lines DC ones formulate an AC/DC hybrid network, based on which flexible power shifting between can be achieved. However, complementarity flows amongst hardly described embedded in existing configuration optimization methods only average loading or variations for certain period considered....
Ice storms can cause serious damage to power distribution systems, thus the development of effective anti-icing and de-icing strategies is great significance. In this article, an optimal coordinated operation scheme proposed enhance resilience systems against ice storms, which based on ice-melting capacity lines. Firstly, a comprehensive risk analysis for in provided. Then, novel critical condition initiation weather forecast deviation potential load loss systems. On basis, optimization...
A pipeline operation optimization model with minimum energy consumption as the objective function was established based on dynamic programming method. The applied to a 3840 km gas whose designed capacity 170 × 10 8 t/a. There were 40 stations in line, including 22 compressor and 32 compressors. solution time controlled within 60 s show that algorithm fast effective. number of starting-up compressors optimized scheme is two more than actual scheme, total pressure drop decreased by 3.40 MPa,...
Network reconfiguration and emergency power vehicles (EPVs) dispatching are widely used in distribution networks for load restoration. However, their capabilities limited by the allocated amounts of circuit breakers EPVs. E-taxis can also participate restoration as a kind mobile energy storage using vehicle to grid (V2G) technology. uncertainty should be considered To achieve better effectiveness fully utilize capability network reconfiguration, EPVs E-taxis, this article proposes...
The increasing proportion of distributed photovoltaics (DPVs) and electric vehicle charging stations in low-voltage distribution networks (LVDNs) has resulted challenges such as transformer overloads voltage violations. To address these problems, we propose a coordinated planning method for flexible interconnections energy storage systems (ESSs) to improve the accommodation capacity DPVs. First, power-transfer characteristics interconnection ESSs are analyzed. equipment costs source...
With the integration of more and renewable energy generations (REGs), structure traditional distribution networks is hard to accommodate volatile power injections REGs. As a new electronic device, soft open point (SOP) can be installed control both active reactive flow among (ADNs). This paper presents comprehensive optimization method for allocating SOPs within an ADN with high penetration In order find proper SOP candidate locations, selection strategy based on two technical indices...
The postdisaster restoration capabilities for critical loads in distribution networks need to be enhanced. In recent years, electric buses (EBs) have been widely used with the carbon-neutral target, which can dispatched and discharged load considering their mobility V2G technology. However, of EBs are limited by transportation system while ac network hardly achieve power transfer between lines due radial constraint. this article, a coordinated method hybrid ac–dc is proposed, has flexible...