J. Balajthy

ORCID: 0000-0001-5787-1251
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Dark Matter and Cosmic Phenomena
  • Atomic and Subatomic Physics Research
  • Particle physics theoretical and experimental studies
  • Particle Detector Development and Performance
  • Radiation Detection and Scintillator Technologies
  • Nuclear Physics and Applications
  • Neutrino Physics Research
  • Cosmology and Gravitation Theories
  • Medical Imaging Techniques and Applications
  • Astrophysics and Cosmic Phenomena
  • Semiconductor materials and interfaces
  • Photocathodes and Microchannel Plates
  • Integrated Circuits and Semiconductor Failure Analysis
  • Luminescence Properties of Advanced Materials
  • Surface Roughness and Optical Measurements
  • Scientific Research and Discoveries
  • Silicon Nanostructures and Photoluminescence
  • Quantum, superfluid, helium dynamics
  • Nuclear and radioactivity studies
  • Infrared Target Detection Methodologies
  • Radiation Effects in Electronics
  • Pneumonia and Respiratory Infections
  • Health, Environment, Cognitive Aging
  • Advanced Power Generation Technologies
  • Advanced X-ray and CT Imaging

Sandia National Laboratories
2022-2024

Sandia National Laboratories California
2022-2024

University of Illinois Urbana-Champaign
2024

University of California, Davis
2018-2022

University of Maryland, College Park
2014-2020

We report constraints on spin-independent weakly interacting massive particle (WIMP)-nucleon scattering using a 3.35×104 kg day exposure of the Large Underground Xenon (LUX) experiment. A dual-phase xenon time projection chamber with 250 active mass is operated at Sanford Research Facility under Lead, South Dakota (USA). With roughly fourfold improvement in sensitivity for high WIMP masses relative to our previous results, this search yields no evidence nuclear recoils. At 50 GeV c−2,...

10.1103/physrevlett.118.021303 article EN publisher-specific-oa Physical Review Letters 2017-01-11

The Large Underground Xenon (LUX) experiment is a dual-phase xenon time-projection chamber operating at the Sanford Research Facility (Lead, South Dakota). LUX cryostat was filled for first time in underground laboratory February 2013. We report results of WIMP search data set, taken during period from April to August 2013, presenting analysis 85.3 live days with fiducial volume 118 kg. A profile-likelihood technique shows our be consistent background-only hypothesis, allowing 90% confidence...

10.1103/physrevlett.112.091303 article EN Physical Review Letters 2014-03-04

We present constraints on weakly interacting massive particles (WIMP)-nucleus scattering from the 2013 data of Large Underground Xenon dark matter experiment, including 1.4×104 kg day search exposure. This new analysis incorporates several advances: single-photon calibration at scintillation wavelength, improved event-reconstruction algorithms, a revised background model events originating detector walls in an enlarged fiducial volume, and calibrations decays injected tritium β source...

10.1103/physrevlett.116.161301 article EN publisher-specific-oa Physical Review Letters 2016-04-20

LUX-ZEPLIN (LZ) is a next-generation dark matter direct detection experiment that will operate 4850 feet underground at the Sanford Underground Research Facility (SURF) in Lead, South Dakota, USA. Using two-phase xenon detector with an active mass of 7 tonnes, LZ search primarily for low-energy interactions weakly interacting massive particles (WIMPs), which are hypothesized to make up our galactic halo. In this paper, projected WIMP sensitivity presented based on latest background estimates...

10.1103/physrevd.101.052002 article EN publisher-specific-oa Physical review. D/Physical review. D. 2020-03-04

We present experimental constraints on the spin-dependent WIMP-nucleon elastic cross sections from total 129.5 kg-year exposure acquired by Large Underground Xenon experiment (LUX), operating at Sanford Research Facility in Lead, South Dakota (USA). A profile likelihood ratio analysis allows 90% CL upper limits to be set WIMP-neutron (WIMP-proton) section of $\sigma_n$ = 1.6$\times 10^{-41}$ cm$^{2}$ ($\sigma_p$ 5$\times 10^{-40}$ cm$^{2}$) 35 GeV$c^{-2}$, almost a sixfold improvement over...

10.1103/physrevlett.118.251302 article EN publisher-specific-oa Physical Review Letters 2017-06-23

10.1016/j.nima.2019.163047 article EN publisher-specific-oa Nuclear Instruments and Methods in Physics Research Section A Accelerators Spectrometers Detectors and Associated Equipment 2019-10-28

The nature of dark matter and properties neutrinos are among the most pressing issues in contemporary particle physics. dual-phase xenon time-projection chamber is leading technology to cover available parameter space for Weakly Interacting Massive Particles (WIMPs), while featuring extensive sensitivity many alternative candidates. These detectors can also study through neutrinoless double-beta decay a variety astrophysical sources. A next-generation xenon-based detector will therefore be...

10.1088/1361-6471/ac841a article EN cc-by Journal of Physics G Nuclear and Particle Physics 2022-12-21

We present experimental constraints on the spin-dependent WIMP (weakly interacting massive particle)-nucleon elastic cross sections from LUX data acquired in 2013. is a dual-phase xenon time projection chamber operating at Sanford Underground Research Facility (Lead, South Dakota), which designed to observe recoil signature of galactic WIMPs scattering nuclei. A profile likelihood ratio analysis 1.4×104 kg day fiducial exposure allows 90% C.L. upper limits be set WIMP-neutron (WIMP-proton)...

10.1103/physrevlett.116.161302 article EN publisher-specific-oa Physical Review Letters 2016-04-20

The scattering of dark matter (DM) particles with sub-GeV masses off nuclei is difficult to detect using liquid xenon-based DM search instruments because the energy transfer during nuclear recoils smaller than typical detector threshold. However, tree-level DM-nucleus diagram can be accompanied by simultaneous emission a bremsstrahlung photon or so-called "Migdal" electron. These provide an electron recoil component experimental signature at higher energies corresponding recoil. presence...

10.1103/physrevlett.122.131301 article EN publisher-specific-oa Physical Review Letters 2019-04-01

The first searches for axions and axionlike particles with the Large Underground Xenon experiment are presented. Under assumption of an axioelectric interaction in xenon, coupling constant between electrons ${g}_{\mathrm{Ae}}$ is tested using data collected 2013 exposure totaling 95 live days $\ifmmode\times\else\texttimes\fi{}118\text{ }\text{ }\mathrm{kg}$. A double-sided, profile likelihood ratio statistic test excludes larger than...

10.1103/physrevlett.118.261301 article EN publisher-specific-oa Physical Review Letters 2017-06-29

We present measurements of the electron-recoil (ER) response LUX dark matter detector based upon 170 000 highly pure and spatially uniform tritium decays. reconstruct energy spectrum using combined model find good agreement with expectations. report average charge light yields ER events in liquid xenon at 180 $105\text{ }\text{ }\mathrm{V}/\mathrm{cm}$ compare results to NEST model. also measure mean recombination fraction its fluctuations, we investigate location width band. These provide...

10.1103/physrevd.93.072009 article EN publisher-specific-oa Physical review. D/Physical review. D. 2016-04-20

Abstract LUX-ZEPLIN (LZ) is a second-generation direct dark matter experiment with spin-independent WIMP-nucleon scattering sensitivity above $${1.4 \times 10^{-48}}\, {\hbox {cm}}^{2}$$ <mml:math xmlns:mml="http://www.w3.org/1998/Math/MathML"> <mml:mrow> <mml:mn>1.4</mml:mn> <mml:mo>×</mml:mo> <mml:msup> <mml:mn>10</mml:mn> <mml:mo>-</mml:mo> <mml:mn>48</mml:mn> </mml:mrow> </mml:msup> <mml:mspace/> <mml:mtext>cm</mml:mtext> <mml:mn>2</mml:mn> </mml:math> for WIMP mass of $${40}\, \hbox...

10.1140/epjc/s10052-020-8420-x article EN cc-by The European Physical Journal C 2020-11-01

Dual-phase xenon detectors, as currently used in direct detection dark matter experiments, have observed elevated rates of background electron events the low energy region. While this negatively impacts detector performance various ways, its origins only been partially studied. In paper we report a systematic investigation pathologies LUX experiment. We characterize different populations based on their emission intensities and correlations with preceding depositions detector. By studying...

10.1103/physrevd.102.092004 article EN Physical review. D/Physical review. D. 2020-11-10

The Large Underground Xenon (LUX) experiment is a dual-phase liquid xenon time projection chamber (TPC) operating at the Sanford Research Facility in Lead, South Dakota. A calibration of nuclear recoils was performed $\textit{in situ}$ LUX detector using collimated beam mono-energetic 2.45 MeV neutrons produced by deuterium-deuterium (D-D) fusion source. recoil energy from first neutron scatter TPC reconstructed measured scattering angle defined double-scatter events within active volume. We...

10.48550/arxiv.1608.05381 preprint EN other-oa arXiv (Cornell University) 2016-01-01

This work presents an analysis of monoenergetic electronic recoil peaks in the dark-matter-search and calibration data from first underground science run Large Underground Xenon (LUX) detector. Liquid xenon charge light yields for energies between 5.2 661.7 keV are measured, as well energy resolution LUX detector at those same energies. Additionally, there is interpretation existing measurements descriptions electron-ion recombination fluctuations liquid limiting cases a more general re-...

10.1103/physrevd.95.012008 article EN publisher-specific-oa Physical review. D/Physical review. D. 2017-01-19

Various dark matter models predict annual and diurnal modulations of interaction rates in Earth-based experiments as a result the Earth's motion halo. Observation such features can provide generic evidence for detection interactions. This paper reports search both rate LUX experiment using over 20 calendar months data acquired between 2013 2016. focuses on electron recoil events at low energies, where leptophilic interactions are expected to occur DAMA has observed strong modulation two...

10.1103/physrevd.98.062005 article EN publisher-specific-oa Physical review. D/Physical review. D. 2018-09-27

The LUX experiment has performed searches for dark-matter particles scattering elastically on xenon nuclei, leading to stringent upper limits the nuclear cross sections dark matter. Here, results derived from $1.4\ifmmode\times\else\texttimes\fi{}{10}^{4}\text{ }\text{ }\mathrm{kg}$ days of target exposure in 2013, details calibration, event-reconstruction, modeling, and statistical tests that underlie are presented. Detector performance is characterized, including measured efficiencies,...

10.1103/physrevd.97.102008 article EN publisher-specific-oa Physical review. D/Physical review. D. 2018-05-31

We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV 33.2 keV. The average electric field applied across target is 180 V/cm. data are obtained using low energy $^{127}$Xe electron capture decay from 95.0-day first run LUX (WS2013) search Weakly Interacting Massive Particles (WIMPs). sequence gamma-ray X-ray cascades associated with $^{127}$I de-excitations produces...

10.1103/physrevd.96.112011 article EN publisher-specific-oa Physical review. D/Physical review. D. 2017-12-28

We present a comprehensive analysis of electronic recoil vs nuclear discrimination in liquid/gas xenon time projection chambers, using calibration data from the 2013 and 2014--2016 runs Large Underground Xenon experiment. observe strong charge-to-light enhancement with increased event energy. For events $\mathrm{S}1=120$ detected photons, i.e., equivalent to energy $\ensuremath{\sim}100\text{ }\mathrm{keV}$, we an background acceptance $<{10}^{\ensuremath{-}5}$ at signal 50%. also modest...

10.1103/physrevd.102.112002 article EN Physical review. D/Physical review. D. 2020-12-01
Coming Soon ...