Ghunter Paulo Viajante

ORCID: 0000-0001-6006-491X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Electric Motor Design and Analysis
  • Induction Heating and Inverter Technology
  • Microgrid Control and Optimization
  • Magnetic Properties and Applications
  • Magnetic Bearings and Levitation Dynamics
  • Advanced DC-DC Converters
  • Multilevel Inverters and Converters
  • Sensorless Control of Electric Motors
  • Photovoltaic System Optimization Techniques
  • Islanding Detection in Power Systems
  • Electric Power Systems and Control
  • Power Systems Fault Detection
  • Business and Management Studies
  • Advanced Battery Technologies Research
  • Non-Destructive Testing Techniques
  • Advancements in Solid Oxide Fuel Cells
  • Smart Parking Systems Research
  • Advanced Scientific and Engineering Studies
  • Academic Research in Diverse Fields
  • Power System Optimization and Stability
  • Electromagnetic Launch and Propulsion Technology
  • Solar Radiation and Photovoltaics
  • Experimental and Theoretical Physics Studies
  • Environmental Sustainability and Education
  • Electronic and Structural Properties of Oxides

Universidade Federal de Uberlândia
2011-2023

Instituto Federal de Goiás
2013-2022

Instituto Federal de Educação, Ciência e Tecnologia do Triângulo Mineiro
2021

Agência Nacional de Energia Elétrica
2021

Endesa (Spain)
2021

Universidade Federal de Goiás
2009

This paper presents a study of the Switched Reluctance Generator dynamics when connected to three-phase AC power grid. A mathematical model that includes magnetic saturation is used represent reluctance generator, which driven by an asymmetric half bridge converter. Output generated voltage smoothed with shunt capacitor leading DC link voltage. regulated using PI compensator governs magnetizing angle generator phases. It shown introducing freewheeling stage between and demagnetizing states...

10.1109/eeeic.2015.7165398 article EN 2015-06-01

This paper reports on a Switched Reluctance Machine (SRM) operating as generator excited through external power source. device provides DC voltage output its converter. Parameters such rotor speed, excitation and firing angles interferes directly the voltage. Thus, many strategies have been studied developed by scientific community in order to control or achieve maximization. work proposes driving strategy applied SRM that consists obtaining optimal maximize for given speed excitation....

10.1109/eeeic-2.2013.6737911 article EN 2013-11-01

This paper presents the analysis and mathematical modeling of synchronous reluctance motor, with state equations results obtained for a 4 pole motor (2 hp), considering framework direct axis quadrature to rotor behavior obtain time values steady electromagnetic torque. It is also observed voltage current in stator way estimate power factor relation inductances.

10.1109/tla.2015.7404914 article EN IEEE Latin America Transactions 2015-12-01

This paper presents a study on the behavior of self-excited switched reluctance generator (SSRG). Following an extensive bibliographic review about SSRGs, mathematical model, principle operation and simulation results dynamics is presented. A capacitor partially charged, in parallel with load used as mean to provide necessary amount magnetic flux start generator's voltage built up. The arrangement such that generated current delivered D.C. mode. To correctly represent self excitation model...

10.1109/cobep.2011.6085193 article EN 2011-09-01

This paper presents a switched reluctance machine (SRM) modeling including core magnetic saturation. The self-excited operation mode generator (SRG) as example application. In addition, following an extensive bibliographic review about (SSRG), the mathematical model, principle of and simulation results dynamics is presented. To correctly represent self excitation model must take into account saturation, that observed here. Experimental are included to validate discussions

10.1109/iecon.2012.6388743 article EN 2012-10-01

This paper presents a strategy to control the terminal voltage of Switched Reluctance Generator. It is implemented using closed loop feedback that senses shunt capacitor smoothed generated at generator terminals. The error feeds PI controller in turn governs switches electronic converter used drive generator. With this approach amount energy stored winding each cycle controlled and leads directly voltage. A mathematical model considers magnetic saturation represent reluctance generator,...

10.1109/iemdc.2013.6556131 article EN 2013-05-01

This study focused on developing a sustainability project carried out in 11 Federal Institute of Education, Science, and Technology Goiás (IFG) campuses wherein energy efficiency distributed generation actions were developed. Energy consumption was optimized by retrofitting the lighting system, installing photovoltaic (PV) quantifying building efficiency, monitoring, training, qualification, focusing efficient use electric energy. We first present Brazilian legislation that regulates...

10.3390/en15031217 article EN cc-by Energies 2022-02-07

This paper presents a scheme to connect the SRG single-phase power grid for active injection. A voltage control of using PI compensator adjust magnetization angles generator phases will be shown. The is subjected variable speed operation verify effectiveness. description P+RES employed as an alternative current injection presented. electric network synchronization obtained through PLL algorithm. simulation and experimental results are presented proving suitable working at connected

10.1109/eeeic.2017.7977397 article EN 2022 IEEE International Conference on Environment and Electrical Engineering and 2022 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) 2017-06-01

This paper presents a Switched Reluctance Machine (SRM) dynamic performance analysis under some operating conditions as fault or lack of phase, different excitement voltage, speed variation. Thus, an SRM 8/6 was designed and built bench to drive it, aiming study the techniques generated voltage control for use in small wind turbine generators. The driving done through data acquisition processing system high low cost (DSP/FPGA). experimental results are shown discussed.

10.1109/eeeic.2018.8493726 article EN 2022 IEEE International Conference on Environment and Electrical Engineering and 2022 IEEE Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) 2018-06-01

This article presents an experimental methodology to control the voltage generated from a switched reluctance generator (SRG) using fuzzy logic control. The is controlled by varying demagnetization angle (<;i>θ<;/i> <sub xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">off</sub> ), maintaining magnetization xmlns:xlink="http://www.w3.org/1999/xlink">on</sub> ) fixed. developed strategy operates on upper switches of asymmetric half-bridge converter....

10.1109/tia.2020.3037263 article EN IEEE Transactions on Industry Applications 2020-11-10

This paper presents a study of the Switched Reluctance Generator dynamics when connected to single-phase AC power grid. A mathematical model that includes magnetic saturation is used represent reluctance generator, which driven by an asymmetric half bridge converter. Output generated voltage smoothed with shunt capacitor leading DC link voltage. regulated using PI compensator governs magnetizing angle generator phases. It shown introducing freewheeling stage between and demagnetizing states...

10.1109/iemdc.2013.6556130 article EN 2013-05-01

This paper presents mathematical modeling and computer simulation of a synchronous reluctance motor, with the state equations results obtained for 4 pole motor (2 hp), considering d/q rotor behavior analysis retrieval time values continuous operation maximum torque.

10.1109/cobep.2015.7420164 article EN 2015-11-01

O objetivo deste artigo é propor uma estratégia de melhoria da conversão eletromecânica energia do Gerador a Relutância Variável (GRV). Esta implementada através controle magnetização cada fase GRV. Para isto, foi utilizado um compensador tipo PI para controlar tensão na carga atuando no ângulo abertura chave superior conversor em ponte assimétrica, half-bridge (HB), o que adiciona etapa roda-livre às etapas operação conversor. No sentido verificar eficiência proposta, foram desenvolvidas...

10.18618/rep.20114.367375 article PT Eletrônica de Potência 2011-11-30

This paper deals with switched reluctance generators. Two aspects of operation are investigated: self excitation and control terminal generated voltage. Self is attractive as it does not require external energy sources. Investigations in a excited generator ask for magnetic saturation iron core to be considered that observed the paper. A technique based on governance magnetization level machine phases voltage proposed. It incorporates strategy improve electromechanical conversion by means...

10.1109/iemdc.2013.6556127 article EN 2013-05-01

This paper deals with the Switched Reluctance Generator (SRG), working in self excitation mode, for controlled generated voltage operation variable speed environment. The inherent behavior observed is existence of high amounts reactive power circulating between machine windings and capacitors that lead to peaks phase currents. These currents, due wide excursions magnetic flux, can impose restrictions applications machine. It this amount not necessary reach given specifications voltages....

10.1109/cobep.2015.7420223 article EN 2015-11-01

Este artigo relata resultados de uma pesquisa no contexto das possibilidades geração distribuída. Uma estratégia para injetar potência ativa na rede alimentação é discutida e testada. A energia proveniente fonte mecânica convertida em elétrica utilizando um Gerador a Relutância Variável. tensão gerada alimenta barramento CC controlada malha fechada. Um conversor CC-CA faz interface do gerador com monofásica, onde o sincronismo obtido através Phase Locked Loop (PLL). O fator unitário...

10.18618/rep.2014.2.121131 article PT Eletrônica de Potência 2014-06-30

O motor a relutância variável (MRV) tem sido considerado uma alternativa viável para substituir os motores elétricos clássicos em aplicações que demandam acionamentos com velocidades variáveis. Este é robusto, dispõe de construção simples e vantagem possuir um rotor não necessita enrolamentos ou ímãs permanentes operar. Neste trabalho, MRV 8/6 tetrafásico projetado fim indução trifásico (MIT), utilizando mesma carcaça disponível. Na metodologia adotada o projeto, dados mecânicos da do MIT...

10.33448/rsd-v11i2.25681 article PT Research Society and Development 2022-01-23

This study addresses a proposal of bench to test single-phase induction motors and switched reluctance with rated power up 1 hp. The was set so that motor tests meet requirements IEEE Std. 114-2001 the Brazilian related Standard (ABNT NBR 5383-2/2008). In addition, procedures for comprise sequential steps in order determine performance under different switching angles constant speed. measurement system is completely computer automated using virtual instrumentation based on LabVIEWtrade...

10.1109/iemdc.2009.5075346 article EN 2009-05-01

This paper presents an analysis of the performance photovoltaic (PV) systems using daily applications periodic linear regression method to indicators Final Yield (YF) and Reference (YR). The research was conducted on PV installed rooftops ground at Federal Institute Education, Science, Technology Goiás (IFG), Itumbiara Campus, from July 2022 August 2023. Energy Monitoring Management Software (SMGE) developed calculate perform analyze systems. results demonstrate that efficiency can be...

10.7769/gesec.v15i10.4158 article EN cc-by-nc-nd Revista de Gestão e Secretariado (Management and Administrative Professional Review) 2024-10-18
Coming Soon ...