Jaime Javaloy

ORCID: 0000-0001-8921-1039
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Corneal surgery and disorders
  • Intraocular Surgery and Lenses
  • Ophthalmology and Visual Impairment Studies
  • Glaucoma and retinal disorders
  • Ocular Infections and Treatments
  • Corneal Surgery and Treatments
  • Ocular Surface and Contact Lens
  • Ocular and Laser Science Research
  • Retinal Imaging and Analysis
  • Retinal and Macular Surgery
  • Reproductive tract infections research
  • Nonmelanoma Skin Cancer Studies
  • COVID-19 Clinical Research Studies
  • Toxoplasma gondii Research Studies
  • Bioeconomy and Sustainability Development
  • Cervical Cancer and HPV Research
  • Space Exploration and Technology
  • Vestibular and auditory disorders
  • Complementary and Alternative Medicine Studies
  • Antibiotics Pharmacokinetics and Efficacy
  • Healthcare and Venom Research
  • Epilepsy research and treatment
  • Potassium and Related Disorders
  • Musculoskeletal pain and rehabilitation
  • Retinal Diseases and Treatments

The Sense Innovation and Research Center
2022

Médecins Sans Frontières
2022

Clínica IVI Alicante
2016-2021

Hospital General Universitario de Alicante Doctor Balmis
2020

Miranza
2005-2014

University of Alicante
1998-2013

Universitat de Miguel Hernández d'Elx
2002-2013

Novem (Netherlands)
2012

Universitat de València
2011

Ferrer Grupo (Spain)
2011

PURPOSE: To evaluate the long-term refractive and visual stability risks related to implantation of Implantable Collamer Lens (ICL; STAAR Surgical, Monrovia, CA) phakic intraocular lens (PIOL) for myopia. METHODS: This retrospective, consecutive, cumulative clinical study was performed in a group 144 eyes implanted with ICL PIOL Only cases data available 12 years after were included series. Corrected distance acuity (CDVA), uncorrected acuity, spherical equivalent, astigmatism, endothelial...

10.3928/1081597x-20150727-05 article EN Journal of Refractive Surgery 2015-08-01

Several infiltrates appeared in the upper midperipheral cornea of a 29-year-old woman who had uneventful corneal collagen crosslinking (CXL) with riboflavin and ultraviolet-A light (UVA) for treatment keratoconus right eye. Staphylococcus epidermidis keratitis was confirmed by microbiological studies, which guided topical fortified antibiotic agents. Before CXL, best spectacle-corrected visual acuity (BSCVA) eye 20/25, manifest refraction −0.25 × 125, anterior segment normal under...

10.1016/j.jcrs.2009.01.036 article EN Journal of Cataract & Refractive Surgery 2009-05-23

ObjectivesSerum levels of potassium (K+) appear to be significantly lower in severe cases acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection and the clinical significance this is unknown. The objective was investigate whether hypokalemia acts as a biomarker severity disease 2019 (COVID-19) pneumonia associated with major outcomes.MethodsA retrospective cohort study inpatients COVID-19 (March 3 May 2, 2020) performed. Patients were categorized according nadir K+ first 72 h...

10.1016/j.ijid.2020.09.033 article EN cc-by-nc-nd International Journal of Infectious Diseases 2020-09-17

To evaluate the reading performance, changes in quality of life, and optical performance after cataract surgery with multifocal diffractive intraocular lens (IOL) implantation.Vissum Corporation, Alicante, Spain.Prospective case series.Patients bilateral had implantation Acri.LISA 366D IOLs. Visual acuity contrast sensitivity outcomes were evaluated during a 6-month follow-up. Other parameters included (Salzburg Reading Desk), 25-item quality-of-life questionnaire (National Eye Institute...

10.1016/j.jcrs.2010.07.035 article EN Journal of Cataract & Refractive Surgery 2010-12-22

To compare the visual outcomes and intraocular optical quality observed postoperatively in patients implanted with a rotationally asymmetric multifocal lens (IOL) an apodized diffractive IOL.Seventy-four consecutive eyes of 40 cataract (age range: 36 to 79 years) were divided into two groups: zonal refractive group, 39 IOL (Lentis Mplus LS-312 IOL, Oculentis GmbH); 35 (ReSTOR SN6AD3, Alcon Laboratories Inc). Distance near acuity outcomes, contrast sensitivity, quality, defocus curves...

10.3928/1081597x-20120110-01 article EN Journal of Refractive Surgery 2012-01-20

PURPOSE: To evaluate in normal healthy eyes the intrasubject repeatability of anterior and posterior corneal curvature measurements other anatomic segment obtained with a new topography system combining Scheimpflug photography Placido-disk technology. SETTING: Vissum Corp., Alicante, Spain. DESIGN: Evaluation METHODS: All received comprehensive ophthalmologic examination including analysis Sirius system. Three consecutive were performed device to assess following parameters: shape factor,...

10.1016/j.jcrs.2011.12.029 article EN Journal of Cataract & Refractive Surgery 2012-06-01

PURPOSE: To compare the visual outcomes and intraocular optical quality in patients with a low-addition (add) power multifocal refractive lens (IOL) rotational asymmetry single-optic accommodating IOL. SETTING: Vissum Instituto Oftalmológico de Alicante, Miguel Hérnandez University, Spain. DESIGN: Prospective comparative nonrandomized consecutive case series. METHODS: Consecutive cataract had implantation of low-add-power IOL (Lentis-Mplus LS-312 MF15) (multifocal group) or (Crystalens HD)...

10.1016/j.jcrs.2011.12.033 article EN Journal of Cataract & Refractive Surgery 2012-06-01

Purpose To evaluate in keratoconus eyes the intrasubject repeatability of anterior and posterior corneal curvature other segment anatomic measurements obtained with a new topography system combining Scheimpflug-photography Placido-disk technology. Setting Vissum Corporation, Alicante, Spain. Design Evaluation Methods All had comprehensive ophthalmologic examination including analysis Sirius system. Three consecutive were to assess following parameters: shape factor, white-to-white (WTW)...

10.1016/j.jcrs.2012.10.033 article EN Journal of Cataract & Refractive Surgery 2012-12-04

ABSTRACT PURPOSE: To assess the effectiveness of optical and ultrasonic pachymetry when examining corneas patients before after laser in situ keratomileusis (LASIK). METHODS: We conducted a prospective study 25 (50 eyes) who had LASIK for myopia or myopic astigmatism (mean spherical equivalent refraction -4.80 ± 3.60 D; range -1.75 to -12.00 D). Corneal thickness was measured using 1) conventional (20 MHz probe) central cornea, 2) ASL confocal microscopy (CMTF analysis), 3) Orbscan II...

10.3928/1081-597x-20040101-06 article EN Journal of Refractive Surgery 2004-01-01

We report a severe anaphylactic reaction that occurred about 5 minutes after 1.0 mg of cefuroxime was injected into the anterior chamber routine phacoemulsification and intraocular lens implantation. The patient known to be allergic penicillin. Immediate action taken, recovered well. presence staff trained in resuscitation essential this case raises questions trend perform topical anesthesia cataract surgery without an anesthesiologist operating room.

10.1016/j.jcrs.2004.06.086 article EN Journal of Cataract & Refractive Surgery 2005-03-01

ABSTRACT PURPOSE: To analyze the quality of LASIK flaps created using a femtosecond laser or mechanical microkeratome. METHODS: A prospective study consecutive bilateral (100 patients) with 15 kHz (IntraLase) microkeratome (Moria M2) was performed. Outcome measures included visual and refractive outcomes, flap dimensions, intraoperative complications. The first ten patients (20 eyes) were examined confocal microscopy 1 3 months following surgery. RESULTS: No significant differences noted in...

10.3928/1081-597x-20070201-10 article EN Journal of Refractive Surgery 2007-02-01

To determine the main causes of intrastromal corneal ring segment (ICRS) explantation and relationship with microscopic findings on ICRS surface.Vissum Corporation-Instituto Oftalmológico de Alicante, Spain.This study evaluated that were explanted in centers Spain from 2000 to 2008. Clinical data (reasons for explantation, date implantation/explantation, tunnel creation technique, type) scanning electron microscopy surface (adherent tissue-like material, cell deposits, protein)...

10.1016/j.jcrs.2009.12.042 article EN Journal of Cataract & Refractive Surgery 2010-05-22

To compare the visual acuity outcomes as well ocular optical performance of eyes implanted with either a monofocal or one two diffractive multifocal intraocular lenses (IOLs).One hundred consecutive 51 bilateral cataract patients (age 49 to 80 years) were divided into three groups: 22 IOL (monofocal group), 40 Acrysof ReSTOR SN6AD3 (ReSTOR and Acri.Lisa 366D (Acri.Lisa group). Visual contrast sensitivity evaluated pre- postoperatively. Additionally, quality aberrations...

10.3928/1081597x-20101223-01 article EN Journal of Refractive Surgery 2011-01-06

PURPOSE: To compare the clinical outcomes after cataract surgery with implantation of 2 models a new rotationally asymmetric multifocal IOL to ascertain which provides better visual performance and patient satisfaction. SETTING: Vissum Instituto Oftalmologico de Alicante, Spain. DESIGN: Comparative case series. METHODS: Consecutive eyes patients were divided into groups. Group A received Lentis Mplus LS-312 MF15 (with near addition [add] power +1.50 diopters [D]) B, MF30 add +3.00 D)....

10.1016/j.jcrs.2011.03.054 article EN Journal of Cataract & Refractive Surgery 2011-08-18

To evaluate and compare the clinical confocal microscopic outcomes achieved with two different procedures for cross-linking (CXL) in eyes keratoconus: CXL epithelial debridement intrastromal pocket.This retrospective study included 27 of 21 patients (age range: 18 to 53 years) diagnosed keratoconus who underwent implantation intracorneal ring segments techniques: previous (classic group, 16 eyes) pocket riboflavin infusion (pocket 11 eyes). Visual, refractive, topographic, aberrometric,...

10.3928/1081597x-20110705-01 article EN Journal of Refractive Surgery 2011-07-13

To evaluate the clinical outcomes of laser in situ keratomileusis (LASIK) for high hyperopia using an excimer and optimized aspheric profiles.Vissum Corporation Miguel Hernández University, Alicante, Spain, Research Institute Ophthalmology, Giza, Egypt.Case series.Eyes patients with or hyperopic astigmatism (spherical equivalent [SE] ≥ 5.64 diopters [D]) had uneventful LASIK ablation profile centered on corneal vertex Amaris 500 kHz a femtosecond platform flap creation temporal hinge.There...

10.1016/j.jcrs.2012.10.045 article EN Journal of Cataract & Refractive Surgery 2013-02-01

Analysis of the femtosecond laser refractive lens surgery corneal incision configuration and higher-order aberration (HOA) effect from first postoperative day.High-resolution anterior segment optical coherence tomography was used to assess 20 eyes undergoing with 2.2-mm minimal incision. The primary (tri-planar) actual length, cord surface angle, irregularity, regional pachymetry values secondary (uni-planar) were analyzed. Hartmann-Shack aberrometer HOAs correlate effect. Assessment done...

10.3928/1081597x-20130819-01 article EN Journal of Refractive Surgery 2013-09-01

ABSTRACT PURPOSE: To evaluate the visual and refractive stability potential long-term risks associated with ZB5M phakic intraocular lens (PIOL) implantation. METHODS: A retrospective, non-randomized, cumulative clinical study was performed over 12 years in a consecutive group of 225 eyes implanted PIOL. The main analyzed variables were outcomes (best spectacle-corrected acuity [BSCVA], uncorrected [UCVA], spherical equivalent), endothelial cell density, postoperative complications. RESULTS:...

10.3928/1081-597x-20070201-07 article EN Journal of Refractive Surgery 2007-02-01

To compare the visual and intraocular optical quality outcomes with different designs of refractive rotationally asymmetric multifocal lens (MFIOL) (Lentis Mplus; Oculentis GmbH, Berlin, Germany) or without capsular tension ring (CTR) implantation.One hundred thirty-five consecutive eyes 78 patients cataract (ages 36 to 82 years) were divided into three groups: 43 implanted C-Loop haptic design CTR (C-Loop only group); 47 45 plate-haptic (plate-haptic group). Visual acuity, contrast...

10.3928/1081597x-20130318-04 article EN Journal of Refractive Surgery 2013-04-01
Coming Soon ...