Ivan Buzurović

ORCID: 0000-0001-9632-3434
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Advanced Radiotherapy Techniques
  • Prostate Cancer Diagnosis and Treatment
  • Stability and Control of Uncertain Systems
  • Medical Imaging Techniques and Applications
  • Endometrial and Cervical Cancer Treatments
  • Radiomics and Machine Learning in Medical Imaging
  • Soft Robotics and Applications
  • Radiation Therapy and Dosimetry
  • Nonmelanoma Skin Cancer Studies
  • Neural Networks Stability and Synchronization
  • Prostate Cancer Treatment and Research
  • Radiation Dose and Imaging
  • Quantum chaos and dynamical systems
  • Control and Stability of Dynamical Systems
  • Management of metastatic bone disease
  • Lung Cancer Diagnosis and Treatment
  • Advanced X-ray and CT Imaging
  • Ovarian cancer diagnosis and treatment
  • Surgical Simulation and Training
  • Photoacoustic and Ultrasonic Imaging
  • Cutaneous lymphoproliferative disorders research
  • Stability and Controllability of Differential Equations
  • MRI in cancer diagnosis
  • Cutaneous Melanoma Detection and Management
  • Nail Diseases and Treatments

Dana-Farber Brigham Cancer Center
2016-2025

Dana-Farber Cancer Institute
2015-2025

Harvard University
2016-2025

Brigham and Women's Hospital
2015-2025

Advanced Radiation Therapy (United States)
2023-2024

Gynecologic Oncology Group
2023-2024

NYU Langone Health
2023-2024

Stellar Science (United States)
2023-2024

Spanish Oncology Genitourinary Group
2023-2024

Memorial Sloan Kettering Cancer Center
2023

Respiratory and cardiac motions induce displacement deformation of the tumor volumes in various internal organs. To accommodate this undesired movement other errors, physicians incorporate a large margin around to delineate planning target volume, so that clinical volume receives prescribed radiation dose under any scenario. Consequently, healthy tissue is irradiated sometimes it difficult spare critical organs adjacent tumor. In study we have proposed novel approach 4D active tracking...

10.1088/0031-9155/56/5/005 article EN Physics in Medicine and Biology 2011-02-01

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education, and practice medical physics. AAPM has more than 8000 members principal organization physicists United States. will periodically define new guidelines for physics help science improve quality service patients throughout Existing (MPPGs) be reviewed purpose revision or renewal, as appropriate, on their fifth anniversary sooner. Each...

10.1002/acm2.13829 article EN cc-by Journal of Applied Clinical Medical Physics 2023-02-20

The surface brachytherapy Task Group report number 253 discusses the common treatment modalities and applicators typically used to treat lesions on body surface. Details of commissioning calibration systems are discussed examples given for a risk‐based analysis approach quality assurance measures that necessary consider when establishing program.

10.1002/mp.14436 article EN Medical Physics 2020-08-29

Recent advances in surface high-dose-rate (HDR) brachytherapy imaging indicate that flap applicators, human skin, and fibromatosis can be visualized using MRI. Complete MR-only workflows would require skin marker identification to define clinical target edges. However, CT markers are not detected on MR images, common unsuitable for continuous tracing. In this paper, we proposed an alternative was evaluated MRI detectability contourability a treatment planning system (TPS). Commercially...

10.5114/jcb.2025.148107 article EN cc-by-nc-sa Journal of Contemporary Brachytherapy 2025-01-01

Purpose: This study presents the implementation and experimental results of a novel technique for 4D tumor tracking using commercially available commonly used treatment couch evaluates accuracy in clinical settings. Methods: Commercially is capable positioning patient accurately; however, currently there no provision compensating physiological movement real‐time. In this paper, real‐time control presented together with motion compensation four dimensions (superior‐inferior, lateral,...

10.1118/1.4758064 article EN Medical Physics 2012-10-26

AMA Lavelle M, Kaza E, Guthier C, et al. Feasibility and clinical implementation of MRI-guided surface brachytherapy. Journal Contemporary Brachytherapy. 2024. doi:10.5114/jcb.2024.135647. APA Lavelle, M., Kaza, E., Guthier, C., O’Farrell, D., Harris, T., & A. Cormack, R. (2024). https://doi.org/10.5114/jcb.2024.135647 Chicago Michael J., Evangelia Christian V. Desmond Thomas C. Robert Phillip M. Devlin "Feasibility brachytherapy". Harvard R., Devlin, P., Buzurovic, I. MLA J. brachytherapy."...

10.5114/jcb.2024.135647 article EN cc-by-nc-sa Journal of Contemporary Brachytherapy 2024-01-01

Respiratory and cardiac motions induce displacement deformation of the tumor-volume in various internal organs. To accommodate this undesired movement other errors, physicians incorporate a large margin around tumor to delineate Planning Target Volume (PTV), so that Clinical (CTV) receives prescribed radiation dose under any scenario. Consequently, volume healthy tissue is irradiated sometimes it difficult spare critical organs adjacent tumor. In study we have proposed novel approach 4D...

10.1109/bibe.2010.52 article EN 2010-01-01

In contemporary brachytherapy procedure, needle placement at desired location is challenging due to a variety of reasons. We have designed and fabricated an image-guided robot-assisted system improve the seed delivery. this article we used two different predictive control strategies in order investigate insertion efficacy dynamics during prostate brachytherapy. First, neural network (NNPC) predict force. The NNPC uses linearized state-space model robotic future performances. Second,...

10.1155/2010/581840 article EN cc-by Journal of Robotics 2010-01-01

Purpose: Recently, several robotic systems have been developed to perform accurate and consistent image‐guided brachytherapy. Before introducing a new device into clinical operations, it is important assess the reliability mean time before failure (MTBF) of system. In this article, authors present preclinical evaluation analysis MTBF an autonomous system, which for prostate seed implantation. Methods: The considered three steps that are in growth analysis. These are: Identification isolation...

10.1118/1.3523097 article EN Medical Physics 2010-12-16

Prostate volume can affect whether patients qualify for brachytherapy (desired size ≥20 mL and ≤60 mL) and/or active surveillance PSA density ≤0.15 very low risk disease). This study examines variability in prostate measurements depending on imaging modality used (ultrasound versus MRI) calculation technique (contouring ellipsoid) quantifies the impact of this treatment recommendations men with favorable-risk cancer. We examined 70 who presented consecutively consideration cancer had...

10.1186/1748-717x-9-200 article EN cc-by Radiation Oncology 2014-09-09

10.1016/j.ijrobp.2010.07.1876 article EN International Journal of Radiation Oncology*Biology*Physics 2010-10-01

ENWEndNote BIBJabRef, Mendeley RISPapers, Reference Manager, RefWorks, Zotero AMA Buzurovic I, Hansen J, Bhagwat M, et al. Clinical implementation of a novel applicator in high-dose-rate brachytherapy treatment esophageal cancer. Journal Contemporary Brachytherapy. 2016;8(4):319-325. doi:10.5114/jcb.2016.61933. APA Buzurovic, I., Hansen, J., Bhagwat, M., O’Farrell, D., Friesen, S., & Harris, T. (2016). Brachytherapy, 8(4), 319-325. https://doi.org/10.5114/jcb.2016.61933 Chicago Ivan Jorgen...

10.5114/jcb.2016.61933 article EN cc-by-nc-sa Journal of Contemporary Brachytherapy 2016-01-01

Biopsies are the gold standard for clinical diagnosis. However, a discrepancy between biopsy sample and target tissue because of misplacement spoon can lead to errors in diagnosis subsequent treatment. Thus, correctly determining whether needle tip is tumor crucial accurate results.A system was designed with steerable, flexible, superelastic concentric tube; electrodes monitor electrical resistivity; load cells insertion force. The degrees freedom were analyzed two working modes:...

10.1109/tbme.2021.3060541 article EN IEEE Transactions on Biomedical Engineering 2021-02-20

Tumors in thorax region incur significant amount of motion and deformation due to respiratory cardiac cycles. To accommodate this undesired movement, physicians incorporate a large standard margin around the tumor delineate Planning Target Volume (PTV), so that Clinical (CTV) receives prescribed dose under any scenario. Consequently, volume healthy tissue might be irradiated sometimes it is difficult spare critical organs adjacent tumor. For compensating motion, techniques such as...

10.1109/robot.2008.4543588 article EN 2008-05-01
Coming Soon ...