Neal Dowling

ORCID: 0000-0001-9681-505X
Publications
Citations
Views
---
Saved
---
About
Contact & Profiles
Research Areas
  • Power System Reliability and Maintenance
  • Reliability and Maintenance Optimization
  • Smart Grid Security and Resilience
  • Islanding Detection in Power Systems
  • Microgrid Control and Optimization
  • Electricity Theft Detection Techniques
  • Transportation Systems and Infrastructure
  • Non-Destructive Testing Techniques
  • Oil and Gas Production Techniques
  • Advancements in Solid Oxide Fuel Cells
  • Fuel Cells and Related Materials
  • Real-time simulation and control systems
  • Sugarcane Cultivation and Processing
  • Quality and Safety in Healthcare
  • Technology Assessment and Management
  • Machine Fault Diagnosis Techniques
  • Photovoltaic System Optimization Techniques
  • Electrocatalysts for Energy Conversion
  • Risk and Safety Analysis
  • Energy and Environment Impacts

Massachusetts Technology Collaborative
2016-2019

Exelis (United States)
2015

Electrical utility reliability indices such as System Average Interruption Frequency Index, Duration Customer and Momentary Index are adequately defined in IEEE Std. 1366-2012, serve the purpose for which they were developed. However, explosive growth of electronics industry moving toward internet things, along with data center development necessary to support growth, has had significant impact on an aging power distribution system. As world evolves notion smart grid, several new metrics...

10.1109/tia.2016.2551696 article EN IEEE Transactions on Industry Applications 2016-04-07

High reliability (and availability) with low life-cycle costs are general goals for all maintenance programs. An effective preventative (PM) regime balances the cost of elimination degradation failure mechanisms through preemptive intervention. Failures in operation require corrective (CM) and often most expensive to repair. PM is conducted reduce probability specific failures hence CM burden cost. However, actions can themselves introduce additional damage mechanisms. Determining optimum...

10.1109/tia.2015.2483700 article EN IEEE Transactions on Industry Applications 2015-01-01

One of the most common questions in early stages designing a new facility is whether normal utility supply to fire pump reliable enough "tap ahead main" or so unreliable that it must have an emergency power source, typically on-site generator. Apart from obligation meet life safety objectives, not uncommon capital on order $100 000 $1 million at stake for backup source. Until now, decision has only been answered with intuition - using combination outage history and anecdotes about what...

10.1109/tia.2013.2241713 article EN IEEE Transactions on Industry Applications 2013-02-01

One of the most common questions in early stages designing a new facility is whether normal utility supply to fire pump reliable enough “tap ahead main” or so unreliable that it must have an emergency power source; typically on-site generator. Apart from obligation meet life safety objectives, not uncommon capital on order $100,000 $1 million at stake for backup source. Until now, decision has only been answered with intuition- using combination outage history and anecdotes about what worked...

10.1109/icps.2012.6229612 article EN 2012-05-01

Reliability-Centered Maintenance (RCM) is a proven technology to optimize the maintenance processes and another logical step in improving overall performance reliability of critical facility while reducing total cost ownership. This paper will introduce RCM use an automatic transfer switch standby generator back up utility power as example system demonstrate process.

10.1109/tia.2014.2379951 article EN IEEE Transactions on Industry Applications 2014-12-12

High reliability (and availability) with low life-cycle costs are general goals for all maintenance programs. An effective Preventative Maintenance (PM) regime balances the cost of elimination degradation failure mechanisms through preemptive intervention. Failures in operation require corrective (CM) and often most expensive to repair. PM is conducted reduce probability specific failures hence CM burden cost. However, actions can themselves introduce additional damage mechanisms....

10.1109/icps.2015.7266415 article EN 2015-05-01

PowerSecure (PS), a subsidiary of Southern Company, operates over 1600 microgrids including large fleet standby diesel generators. Machines range from 125 to 2800 kW. There are two missions: power after utility failure and load management when is available. This report updates generator reliability data published 20 years ago. These results first derived uniform records distributed acquisition system. The unique aspects this effort include automated collection, analysis, storage producing...

10.1109/tia.2019.2957469 article EN cc-by IEEE Transactions on Industry Applications 2019-12-04

PowerSecure (PS), a subsidiary of Southern Company, operates over 1600 microgrids and as result manages large fleet standby diesel generators. The machines range in power from 125 to 2800 kW. Most the are used two different missions. In addition providing after utility failure, most serve one or more utility-driven load management applications, including demand response, coincident peak capacity markets, automatic frequency generation during spot market prices. MTechnology, Inc., was...

10.1109/ias.2019.8912369 article EN IEEE Industry Applications Society Annual Meeting 2019-09-01

Reliability Centered Maintenance (RCM) is a proven technology to optimize the maintenance processes and another logical step in improving overall performance reliability of critical facility while reducing total cost ownership (TCO). This paper will introduce RCM use an Automatic Transfer Switch (ATS) standby generator back up utility power as example system demonstrate process.

10.1109/ias.2014.6978495 article EN 2014-10-01

Electrical utility reliability indices, such as SAIFI, SAIDI, CAIDI, CAIFI, and MAIFI are adequately defined in IEEE Std 1366-2012 [1] serve the purpose for which they were developed. However, explosive growth of electronics industry moving toward an "internet things," along with data center development necessary to support has had significant impact on aging power distribution system. As world evolves notion "smart grid," several new metrics needed evaluate electrical customer's side meter.

10.1109/ias.2015.7356924 article EN IEEE Industry Applications Society Annual Meeting 2015-10-01

This paper describes a test facility designed and operated by MTechnology, Inc. (MTech) for development testing of grid-connected Distributed Energy Resources (DER). The is capable inverters, loads, related DER connection equipment up to 500 kVA, with an upgrade 2000 kVA in progress. includes simulation, desktop equipment, benchtop fixtures that utilize full-scale hardware at reduced voltage current, synthetic grid full power under transient fault conditions, direct the local utility...

10.1109/citres.2010.5619776 article EN 2010-09-01

This article presents an idea of achieving reliability through Industrial Internet Things (IIoT) for industrial power systems. It proposes hybrid approach predictive and corrective maintenance. discusses the self-corrective maintenance (SCM) paradigm as systems along with condition-based utilizing IIoT to achieve it. As it is well known that industries pay huge penalty down time, suffer meet demands years. Study witnesses its cost in millions dollars yearly production disruptions. can be...

10.1109/icps.2019.8733363 article EN 2019-05-01

A power plant comprising two 200 kW/230 kVA fuel cells was installed and operated over a period of 15 months. Details the operating experience economics application are discussed.

10.1109/citres.2010.5619796 article EN 2010-09-01

MTechnology, Inc., was retained to design and develop the power electronics system for a distributed generation plant. The plant incorporated four 250 kW DC modules. required operate both in grid-connect grid-independent modes, with constraints upon acceptable transients applied internal bus during transitions between modes. transition from mode control assume responsibility voltage regulation balance ancillary loads. Operation faced challenge of starting relatively large compressor fan...

10.1109/citres.2010.5619800 article EN 2010-09-01